ODM SJKM1E Molded Case Circuit Breaker ECB Suppliers, Supplier

The SJKM1E Molded Case Circuit Breaker ECB delivers comprehensive circuit protection for 400V AC systems (50/60Hz, up to 800A). Featuring adjustable overcurrent, short-circuit (instantaneous/delayed), and optional undervoltage/phase-failure protection, this SJKM1E ECB ensures reliable power distribution with minimized downtime. Available in M-type and H-type (high-breaking capacity) versions, it offers 800V insulation and superior arc resistance. With vertical/horizontal installation options and isolation capability (symbol: -), this IEC60947-compliant circuit breaker supports industrial automation through "Z"/"B" type units with communication interfaces for remote monitoring. 

Product Description

Type Designation

SJKM1E Type Designation
1 Business Code
2 Molded Case Circuit Breaker (MCCB) Designation
3 Design Code
4 Electronic Release
5 Frame Current Rating (A)
6 Rated Ultimate Three-Phase Breaking Capacity Class (Note 1)
7 Operation Mode (Note 2)
8 Number of Poles
9 Release Mechanism Type and Accessory Code
10 Product Type (Note 3)

Usage Environment Conditions

Altitude: ≤ 2000 m; Ambient temperature: -5°C ~ +40°C
Resistant to the effects of humid air
Resistant to the effects of salt mist and oil mist
The installation category of the main circuit of the circuit breaker is III, and the installation categories of the remaining auxiliary circuits and control circuits are II
When the maximum temperature is +40°C, the relative air humidity shall not exceed 50%. A higher relative humidity is allowed at lower humidities. Special measures should be taken for the occasional occurrence of condensation due to temperature changes
Maximum inclination: 22.5°
In a non-explosive medium, and the medium does not contain gases and conductive dusts that can corrode metals and damage insulation
In a place without rain and snow attacks

Product Display

SJKM1E Molded Case Circuit Breaker ECB (3)
SJKM1E Molded Case Circuit Breaker ECB (2)
SJKM1E Molded Case Circuit Breaker ECB (1)

Product Structure and Marking Instructions

◆ Circuit Breaker Front Indicator (or Circuit Breaker Faceplate Indications)
SJKM1E Structure Diagram 1
SJKM1E Structure Diagram 2
Overload long-time delay trip current I1 adjustment: According to the different rated currents of the circuit breaker, adjustment can be made from 4th to 10th gear.
Long-time delay action time t1 adjustment: 4 gears can be adjusted.
Short-time delay trip current I2 adjustment: 10 gears can be adjusted.
Short-time delay action time t2 adjustment: 4 gears can be adjusted.
Instantaneous trip current I3 adjustment: 8th, 9th, or 10th gear can be adjusted.
Pre-alarm trip current Ir0 adjustment: 7 gears can be adjusted.
Test terminal: Used for undervoltage release testing (or trip unit testing).

Technical Parameters

Model SJKM1E-125 SJKM1E-250
Shell-frame Rated Current Inm (A) 125 250
Rated Current (Adjustable) In (A) 16-32A / 32-63A / 63-125A (adjustable) 100-250A (adjustable)
Rated Operating Voltage Ue (V) AC400V
Rated Insulation Voltage Ui (V) AC800V
Rated Impulse Withstand Voltage Uimp (V) AC800V
Number of Poles 3 4 3 4
Rated Ultimate Short-circuit Breaking Capacity Level M H M H M H M H
Rated Ultimate Short-circuit Breaking Capacity Icu (kA) 50 85 50 85 50 85 50 85
Rated Service Short-circuit Breaking Capacity Ics (kA) 35 50 35 50 35 50 35 50
Rated Short-time Withstand Current Icw (kA)/1s —
Utilization Category A A
Operating Performance (times) Energized 3000 3000
De-energized 7000 7000
Overall dimensions (mm) L 150 165
W 92 122 107 142
H 92 90
Arcing Distance (mm) ≤50 ≤50
SJKM1E-400 SJKM1E-630 SJKM1E-800
400 630 800
200~400A adjustable 400~630A adjustable 630~800A adjustable
AC400V
AC800V
AC800V
3 4 3 4 3 4
M H M H M H M H M H M H
75 85 75 85 80 100 80 100 80 100 80 100
55 65 55 65 60 70 60 70 60 70 60 70
5 8 10
B B B
2000 1500 1500
4000 3000 3000
257 280 280
150 210 280 210 280
16.5 115.5 115.5
≤100 ≤100 ≤100

Overall Dimensions and Installation Dimensions

Overall Dimensions and Installation Dimensions

Frequently Asked Questions (FAQ)

What does the "E" in the SJKM1E model stand for?
The "E" represents the Electronic Release unit, indicating that this Molded Case Circuit Breaker utilizes intelligent electronic protection for precise and adjustable current and time delay tripping settings.
What are the standard ambient operating temperatures for this MCCB?
The circuit breaker operates reliably within an ambient temperature range of -5°C to +40°C. For installation sites, the altitude should not exceed 2000 meters above sea level.
What parameters can be adjusted on the faceplate of the breaker?
The faceplate allows precise settings for overload long-time delay trip current (I1), long-time delay action time (t1), short-time delay trip current (I2), short-time delay action time (t2), instantaneous trip current (I3), and pre-alarm trip current (Ir0).
What is the difference between breaking capacity levels "M" and "H"?
"M" signifies Standard Breaking Capacity, whereas "H" signifies High Breaking Capacity, offering a higher level of ultimate short-circuit current protection (Icu) for more demanding electrical systems.
What frame current ratings are available in the SJKM1E series?
The series features frame current ratings ranging from 125A up to 800A (specifically 125A, 250A, 400A, 630A, and 800A), available in both 3-pole and 4-pole configurations.

Related Products