High-Quality SJKM5 Industrial MCCB Breaker for Short-Circuit Protection Manufacturers, Manufacturer

SJKM5 Molded Case Circuit Breaker (MCCB) delivers robust 3P/4P protection for 100A-630A applications, featuring 800V insulation and 8kV impulse withstand. This IEC 60947-2 certified MCCB offers 1000V breaking capacity (AC 50/60Hz) with Icu/Ics protection levels. The Molded Case Circuit Breaker operates reliably in pollution degree 3 environments at 40°C, meeting NEMA AB1 standards. Its thermal-magnetic trip system ensures precise overload and short-circuit protection for 380V-690V industrial systems. The SJKM5 MCCB combines isolation capability with durable construction, making it ideal for power distribution panels, manufacturing plants, and commercial installations requiring high-performance circuit protection.

Product Description

Type Designation

SJKM5 Industrial MCCB Breaker Type Designation
1Manufacturer Code
2Molded Case Circuit Breaker Code
3Design Code
4Frame Size
5Short-Circuit Breaking Capacity Level 4
6Operation method 3
7Number of Poles 2
8Trip Unit Method & File Code
9Function Code 1

Product Display

Characteristic

Rated insulation voltage (V)UI800
Rated impulse voltage (kV)Uimp8
Rated working voltage (V)UeAC 50/60 Hz690
Applicable for IsolationIEC/EN 60947-2YES
Application CategoryA
Pollution DegreeIEC 60664-13

Technical Parameters

Circuit Breaker
Breaking Capacity Level
Electrical performance complies with IEC 60947-2
Rated current (A)In40℃
Pole number
Limit breaking capacity (kA rms)
IcuAC 50/60 Hz220/240V 380/415V 660/690V 800V 1000V
Service breaking capacity (kA rms)
Mechanical electricalIcs%Icu
415VIn
440VIn/2
In
690VIn/2
In
Electrical performance complies with Nema AB1
Breaking capacity (kA rms)AC 50/60 Hz240V 480V 600V 800V 1000V
Protection and measurement
Short-circuit protectionMagnetic protection
Overload/short-circuit protectionThermal magnetic
Electronic
Electronic with neutral protection (off-0.5-1-OSN)
With earth fault protection
With zone selective interlock (ZS1)
Display / l,U,P,F,E measurement / fault current measurement
OptionsCabinet door display unit
Operation management
Counter
Historical logs and alarms
Measurement communication
Switch status/control communication
Leakage protectionVia Vig leakage protection module
Via Vigirex leakage relay
Installation/connection
Dimensions and weight
Dimensions (mm) W×H×DFixed front connection2/3P 4P
Weight (kg)Fixed front connection2/3P 4P
Connection
Connection terminalsPole spacingWith/without terminal expander
Copper or aluminum cablesCross-sectional areamm²
SJKM5-100 SJKM5-160 SJKM5-250 SJKM5-400 SJKM5-630
FNHSL NFHSL NFHSL NFHSL NFHSL
100 160 250 400 630
3,4 3,4 3,4 3,4 3,4
85 85 100 120 150 36 50 70 100 150 35 42 65 90 130 25 30 50 65 70 8 10 10 15 35 30 15 85 85 100 120 150 36 50 70 100 150 35 42 65 90 130 25 30 50 65 70 8 10 10 15 35 30 15 85 85 100 120 150 36 50 70 100 150 35 42 65 90 130 25 30 50 65 70 8 10 10 15 35 30 15 85 85 100 120 150 36 50 70 100 150 35 42 65 90 130 25 30 50 65 70 8 10 10 15 35 30 25 85 85 100 120 150 36 50 70 100 150 35 42 65 90 130 25 30 50 65 70 8 10 10 15 35 30 25
100% 100% 100% 100% 100%
50000 40000 20000 15000 15000
30000 20000 10000 7000 7000
50000 30000 40000 20000 20000 10000 12000 6000 8000 4000
20000 10000 15000 7500 10000 5000 6000 3000 6000 2000
85 90 100 120 150 35 50 65 90 130 8 20 35 40 35 25 12 85 90 100 120 150 35 50 65 90 130 8 20 35 40 35 25 12 85 90 100 120 150 35 50 65 90 130 8 20 35 40 35 25 12 85 90 100 120 150 35 50 65 90 130 8 20 35 40 35 30 15 85 90 100 120 150 35 50 65 90 130 8 20 35 40 35 30 15
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
105×161×86 / 140×161×86 105×161×86 / 140×161×86 105×161×86 / 140×161×86 140×255×110 / 185×255×110 140×255×110 / 185×255×110
2.05 / 2.4 2.2 / 2.6 2.4 / 2.8 6.05 / 7.9 6.2 / 8.13
35/45mm 35/45mm 35/45mm 45/52.5mm 45/70mm 45/52.5mm 45/70mm
300 300 300 4×240 4×240

Ordering Instructions

Order Specifications Required from Customers:

a) Product Name: Model Number, Rated Current;
b) Rated Current, Number of Poles;
c) Minimum Order Quantity.

Example:
Order SJKM5-100 3-pole circuit breaker, type F, rated current 100A, quantity 1000 units.
Should be written as: SJKM5-100F/3P, 100A, 1000 units.

Frequently Asked Questions (FAQ)

Q: What standards does the SJKM5 series circuit breaker comply with?
The SJKM5 series complies with international standards including IEC/EN 60947-2, NEMA AB1, and IEC 60664-1 for pollution degree classification.
Q: What frame sizes and ratings are available for this series?
The product family offers multiple frame sizes including SJKM5-100, SJKM5-160, SJKM5-250, SJKM5-400, and SJKM5-630, supporting continuous current ratings from 100A up to 630A.
Q: What are the pole configuration options?
The SJKM5 series is available in both 3-pole (3P) and 4-pole (4P) configurations to meet diverse three-phase industrial distribution requirements.
Q: What types of protection units are supported?
This series supports thermal-magnetic trip units, electronic trip units, electronic trip units with neutral protection (off-0.5-1-OSN), earth fault protection, and zone selective interlocking (ZS1).
Q: Can leakage protection be added to the SJKM5 series?
Yes, leakage protection functions can be integrated using either an external Vig leakage protection module or via a Vigirex leakage relay.
Q: How do I correctly specify an order model?
State the product model, breaking capacity type, number of poles, rated current, and required quantity. For example: "SJKM5-100F/3P, 100A, 1000 units".

Related Products