High-Quality SJKM8 Moulded Case Circuit Breaker MCCB Suppliers, Company

The SJKM8 Moulded Case Circuit Breaker (MCCB) delivers reliable circuit protection for 50/60Hz systems with 690V insulation and current ratings from 100A to 630A. Available in 1P, 2P, 3P, and 4P configurations, this MCCB supports manual, fixed, and plug-in mounting options for versatile panel integration. Compliant with IEC60947-2 & EN60947-2, the SJKM8 MCCB ensures robust performance in industrial and commercial applications. Its durable design provides overload and short-circuit protection, making it ideal for power distribution systems requiring high breaking capacity. The compact construction allows space-saving installation while maintaining superior arc-quenching performance.

Product Description

Type Designation
SJKM8 Moulded Case Circuit Breaker Model Designation
1 Manufacturer Code
2 Molded Case Circuit Breaker Code
3 Design Code
4 Frame Size
5 Short-Circuit Breaking Capacity Level 4
6 Operation method 3
7 Number of Poles 2
8 Trip Unit Method & File Code
Technical Parameters
SJKM8 Series Circuit Breaker SJKM8-100 SJKM8E-160/250 SJKM8-160/250 SJKM8-400 SJKM8-630
Pole Number 1, 2, 3, 4 3 3, 4 3, 4 3, 4
Control Manual Toggle handle ■ ■ ■ ■ ■
Direct or extended rotary handle ■ ■ ■ ■ ■
Type Fixed Front connection ■ ■ ■ ■ ■
Rear connection - ■ ■ ■ ■
Plug-in Front connection ■ ■ ■ ■ ■
Rear connection - ■ ■ ■ ■
Electrical performance complies with IEC 60947-2 and EN 60947-2 standards
Rated Current (A) In 40℃ 100 160/250 160/250 400 630
Rated Insulation Voltage (V) Ui 690 690 690 690 690
Rated Impulse Withstand Voltage (kV) Uimp 6 6 6 6 6
Rated Working Voltage (V) Ue AC 50/60Hz 500 500 500 500 500
Circuit Breaker Type NH NH NH NH NH
Ultimate Breaking Capacity (kA rms) Icu AC 50/60Hz 220/240V 5065 5085 5085 85100 85100
380/400V 2535 2536 2536 3650 3650
415V 2530 2536 2536 3650 3650
440V 2020 2025 2025 3650 3650
500V 1010 810 810 2036 2036
Service Breaking Capacity (kA rms) Ics AC 50/60Hz 220/240V 2530 2543 2543 4350 4350
380/400V 1317 1318 1318 1825 1825
415V 77 1318 1318 1825 1825
440V 55 1013 1013 1825 1825
500V 33 45 45 1018 1018
Isolation Function ■ ■ ■ ■ ■
Application Category A A A A A
Maximum Expected Maintenance Value (C-O Cycle) Mechanical 8500 10000 10000 6000 6000
Electrical 440V In 4000 5000 5000 1000 1000
Protection
Release Thermo-magnetic Thermo-magnetic Thermo-magnetic Thermo-magnetic Thermo-magnetic
Overload Protection Long-time Delay Ir(In×…) ■ ■ ■ ■ ■
Short-Circuit Protection Short-time Delay Isd(In×…) - - - - -
Instantaneous Ii(In×…) ■ ■ ■ ■ ■
Leakage Protection Circuit Breaker with Complete Leakage Protection - - ■ ■ ■
Vigirex Relay ■ ■ ■ ■ ■
Indication and Control Auxiliaries
Auxiliary Contact (FZ) and Alarm Contact (BJ) ■ ■ ■ ■ ■
Auxiliary Alarm Contact (FZ/BJ) ■ ■ ■ ■ ■
Shunt Trip Coil (FL) ■ ■ ■ ■ ■
Under-Voltage Coil (QY) ■ ■ ■ ■ ■
Modbus Communication
Pm200 Meter Electrical Measurement (Current, Voltage, Power, Energy) ■ ■ ■ ■ ■
Mc Multi-Circuit Monitoring Unit Status ■ ■ ■ ■ ■
Electrical Measurement (Current, Voltage) ■ ■ ■ ■ ■
Installation
Accessories Terminal Expansion and Extension ■ ■ ■ ■ ■
Terminal Cover ■ ■ ■ ■ ■
Phase Separator ■ ■ ■ ■ ■
Circuit Breaker Type N/H N/H N/H N/H N/H
Dimensions (mm) W×H×D Fixed Front Connection 1P 25×130×60 - - - -
2P 50×130×60 - - - -
3P 75×130×60 105×165×60 105×165×68 140×257×103 140×257×103
4P 100×130×60 - 140×165×68 185×257×103 185×257×103
Weight (kg) Fixed Front Connection 1P/2P 0.28/0.48 - - - -
3P/4P 0.78/1.0 1.3 1.6/2.1 6.05/7.9 6.5/8.7
Product Display
Ambient Temperature Derating
SJKM8-100~630
Rated Current (A) Environmental Temperature
40℃45℃50℃55℃60℃65℃70℃
1515.715.31514.714.614.213.8
2020.420.22019.919.218.916.5
2525.725.32524.724.524.324.0
3031.430.73029.429.128.528.0
4040.940.44039.538.037.637.1
5052.151.05049.348.147.346.6
6061.860.96059.057.556.655.7
7576.875.97573.570.469.869.1
8082.281.18078.577.375.776.1
10010310110099.294.293.592.7
100106.8103.510096.492.788.884.7
125134.9130125119.8114.3108.5102.5
160170.9165.5160154.3148.3142.1135.6
175175168161154146138126
200215207.6200192183.8175.1165.9
225243.5234.5225215.1204.8193.9182.3
250270.6260.5250239227.5215.4202.6
250268260250240228218208
320342333320307291278266
350375364350336319305291
400428416400384364348332
400400390.5381371.4361.9349.2339.7
500500488.1476.2464.3452.4436.5424.6
630630615600585570550535
SJKM8-100 1P, 2P Fixed-type Power Distribution and Motor Protection
SJKM8-100 1P 2P Installation and Dimensions
① Outline Dimensions ② Chassis Installation ③ DIN Rail Installation ④ Front-of-Panel Opening (Small) ⑤ Front-of-Panel Opening (Large)
SJKM8-100 3P, 4P Fixed-type Power Distribution and Motor Protection
SJKM8-100 3P 4P Installation and Dimensions
① Outline Dimensions ② Chassis Installation ③ DIN Rail Installation ④ Front-of-Panel Opening (Small) ⑤ Front-of-Panel Opening (Large)
Frequently Asked Questions
What international standards does the SJKM8 MCCB comply with?

The SJKM8 series moulded case circuit breakers fully comply with the international standard IEC 60947-2 and the European standard EN 60947-2, ensuring high performance, electrical reliability, and safety.

What pole configurations and frame sizes are available?

The series covers rated frame currents ranging from 100A up to 630A. The SJKM8-100 model supports 1-pole, 2-pole, 3-pole, and 4-pole configurations, while higher frame sizes (160 to 630) are available in 3-pole and 4-pole versions.

What types of electrical protection does the SJKM8 series offer?

It comes equipped with thermo-magnetic release units delivering long-time delay overload protection (Ir) and instantaneous short-circuit protection (Ii). Furthermore, complete leakage protection models or Vigirex relay integrations are supported.

What mounting options and connection methods are supported?

SJKM8 circuit breakers support both fixed and plug-in mounting styles with front or rear wiring connection options. The SJKM8-100 series supports both chassis mounting and standardized DIN rail installation.

Can the SJKM8 be integrated into smart management systems?

Yes, the series supports Modbus communication, PM200 power meters for measuring current, voltage, power, and energy, as well as MC multi-circuit monitoring units for real-time status and telemetry tracking.

How does ambient temperature influence the operating current?

The rated current is calibrated based on a standard 40℃ ambient environment. When operating above 40℃ (up to 70℃), derating factors apply according to the ambient temperature compensation table provided above.