High-Quality MCHF Series High Frequency UPS Power Supply Manufacturer, Companies

The MCHF series (1-10kVA) adopts DSP digital control technology. On the basis of solving 9 major power problems (mains power failure, voltage sag, surge, undervoltage, overvoltage, electronic interference, frequency fluctuation, transient change, harmonic distortion, etc.), it further improves the adaptability and reliability of the product, providing foolproof protection for user equipment and the UPS itself. The MCHF series 1-10k is mainly applied to department-level servers, small local area networks, workstations, industrial control computers, small medical equipment, and other small precision electronic instruments.

Product Description

Protection Features

Power-on Self-Diagnosis: Detects hidden faults of the UPS proactively to eliminate potential hazards before system startup.

Comprehensive Safeguards: Integrates AC input overvoltage/undervoltage, output overload/short-circuit, inverter overheat, battery undervoltage warning, and overcharge protections.

Uninterrupted Bypass: Automatically transitions to bypass mode with real-time acoustic alarms during output overload or hardware failure without dropping load power.

Line Phase Verification: Built-in live/neutral line polarity check prevents reverse connection hazards on mains input wiring.

Cold Start Capability: Equipped with a powerful DC start function allowing equipment activation directly from battery storage without mains presence.

Strong Environmental Adaptability

Wide Input Voltage Range: Operates seamlessly between 115VAC and 300VAC, drastically reducing battery discharge frequency in erratic power environments.

Low Voltage Capability at Half Load: Input voltage can drop down to 115V at 50% load without switching to battery power, preserving energy reserves.

Generator Compatibility: Broad 46Hz–64Hz input frequency response adapts easily to fluctuations from fuel-powered generators.

Product Display

Technical Parameters

MODEL MCC 1K MCC 2K MCC 3K
CAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W
INPUT
Voltage Range 110-300 VAC (Auto sensing)
Frequency Range 46Hz~55Hz or 56Hz~64Hz
Phase Single phase with ground
Power Factor (nominal output @ full load) ≥ 0.99
OUTPUT
Output Voltage 200 / 208 / 220 / 230 / 240 VAC
AC Voltage Regulation (Static) ±1%
Frequency Range (Synchronized Range) 48~52 Hz or 58~62 Hz
Frequency Range (Batt. Mode) 50 Hz ±0.2 Hz or 60 Hz ±0.2 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤2% THD (Linear Load), ≤6% THD (Non-linear Load)
Transfer Time AC Mode to Batt. Mode Zero
AC Mode to Bypass 4 ms (Typical)
Waveform (Batt. Mode) Pure sinewave
EFFICIENCY (Peak)
AC Mode (@100% RCD load) 88% 88% 88%
Battery Mode (@100% RCD load) 83% 83% 83%
BATTERY
Standard Model Battery Type 12V / 9Ah 12V / 9Ah 12V / 9Ah
Battery Numbers 2 4 6
Typical Recharge Time 5 hours recover to 90% capacity
Charging Current 1.0 A
Charging Voltage 27.4 VDC ±1% 54.8 VDC ±1% 82.2 VDC ±1%
Long-run Model Battery Type and Numbers Depending on applications
Charging Current 4.0 A
Charging Voltage 41.1 VDC ±1% 82.2 VDC ±1% 109.6 VDC ±1%
INDICATORS
LED Panel UPS status, Load level, Battery level, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Standard Model DxWxH (mm) 360 × 145 × 227 400 × 190 × 327 400 × 190 × 327
Net Weight (kg) 9.0 17.7 23.9
Long-run Model DxWxH (mm) 360 × 145 × 227 400 × 190 × 327 400 × 190 × 327
Net Weight (kg) 5.2 8.6 8.7
ENVIRONMENT
Operation Humidity 0–95% RH @ 0–40°C (non-condensing)
Noise Level Less than 50 dBA @ 1 Meter
MANAGEMENT
Communication RS232 Card / Optional USB Card, SNMP Card, or AS400 Card available
Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
High Power Models Specification (MCC 6K / MCC 10K)
MODEL MCC 6K MCC 10K
PHASE 1 phase in / 1 phase out
CAPACITY 6000 VA / 4800 W 10000 VA / 8000 W
INPUT
Voltage Range Low Line Transfer 110 VAC ±3% at 50% Load; 176 VAC ±3% at 100% Load
Low Line Comeback 120 VAC ±3% at 50% Load; 186 VAC ±3% at 100% Load
High Line Loss 300 VAC ±3%
High Line Comeback 290 VAC ±3%
Frequency Range 46Hz~54 Hz or 56Hz~64 Hz
Power Factor ≥ 0.99 @ 100% load
OUTPUT
Output Voltage 200 / 208 / 220 / 230 / 240 VAC
AC Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46Hz~54Hz @ 50Hz system; 56Hz~64Hz @ 60Hz system
Frequency Range (Batt. Mode) 50 Hz ±0.1Hz or 60 Hz ±0.1Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤3% THD (Linear Load), ≤6% THD (Non-linear Load)
Transfer Time Bypass to Inverter (Line mode) 0 ms
Inverter to Bypass (Line mode) 0 ms
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
Line Mode 90%
Battery Mode 89%
BATTERY
Standard Model Battery Type 12V / 7Ah 12V / 9Ah
Numbers 16 pcs 16 pcs
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current Default: 1.0 A ±10%, Max.: 2.0A ±10%
Float Charging Voltage 218.4 VDC ±1%
Long-run Model Battery Type Depending on applications
Numbers 16-20 pcs (adjustable)
Charging Current Default: 4.0 A ±10%
Float Charging Voltage 218.4 VDC ±1% (based on 16 pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Standard Model Dimension, DxWxH (mm) 515 × 250 × 608 515 × 250 × 608
Net Weight (kg) 68.0 68.5
Long-run Model Dimension, DxWxH (mm) 530 × 245 × 455 530 × 245 × 455
Net Weight (kg) 18.0 21.5
ENVIRONMENT
Operation Humidity 0–95% RH @ 0–40°C (non-condensing)
Noise Level Less than 55 dBA @ 1 Meter Less than 58 dBA @ 1 Meter
MANAGEMENT
Smart RS-232 Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

Frequently Asked Questions (FAQ)

What is the transfer time from AC mode to battery mode?

The transfer time between AC mode and battery mode is zero (0 ms), delivering continuous, uninterrupted pure sinewave power to protect sensitive equipment.

Can this UPS system run reliably with a fuel generator?

Yes. With an ultra-wide input frequency window of 46Hz to 64Hz, the system maintains stable synchronization and smooth operation with various fuel generators.

What happens during mains power fluctuations or low voltage?

The unit accepts an input voltage range of 110–300 VAC. At half load, it operates down to 115 VAC without draining battery power, preserving capacity for true outages.

What is the difference between Standard Models and Long-run Models?

Standard models include internal batteries designed for typical backup intervals. Long-run models feature an enhanced 4.0A charger and configurable external battery setups for long-duration runtime.

What monitoring and communication options are supported?

It supports RS-232 / Smart RS-232 ports along with optional USB, AS400, and SNMP cards. Power management is compatible with Windows, Linux, Unix, and Mac platforms via local software or web browsers.

How does the UPS alert users in case of faults or abnormal conditions?

The unit provides multi-tier acoustic alarms: battery mode (beeps every 4 seconds), low battery (beeps every second), overload (twice per second), and continuous beeping for fault states, accompanied by real-time status readings on the panel.