Wholesale MCEX/MCTA Series Standby UPS Power Supply Supplier, Manufacturers

The MCEX/MCTA Series Standby UPS Power Supply is a high-performance emergency power supply built for daily home and office use. It adopts wide voltage input design, steady output voltage and fast switching response to handle sudden power outages, grid fluctuations and surge shocks. Featuring low-noise operation and long-lasting battery performance, it effectively avoids device damage caused by unstable power. This practical backup power unit delivers durable, cost-effective and reliable all-round power protection for computers, routers and common small electronic devices.

Product Description

MCEX Series UPS Features

Voltage Regulation Output:

- The MCEX series is a new-generation product with automatic input/output voltage detection and regulated output.

- Specially designed for personal PCs, small workstations, and industrial control users, it features automatic voltage regulation and effectively filters out various power disturbances.

Wide Voltage Input:

- The MCEX supports an input voltage range of 162VAC to 290VAC and a frequency range of 45Hz to 55Hz, delivering reliable and stable power output.

Power-On Self-Test Function:

- At power-up, it automatically simulates power outage conditions to self-test the operational status and battery, making accurate and reliable judgments to fully enhance load safety.

MCTA Series UPS Features

  • Excellent microprocessor control guarantees high reliability
  • Boost and buck AVR for voltage stabilization
  • Auto restart while AC is recovering
  • Simulated sine wave output
  • Off-mode charging function
  • Cold start function enabled
  • Optional USB/RS-232 communication port and RJ-11/RJ-45 phone protection

Product Display

MCEX Series Technical Parameters

MODEL MCEX400 MCEX 600 MCEX 800
Capacity 400VA / 240W 600VA / 360W 800VA / 480W
Input
Voltage 110/120 VAC or 220/230/240 VAC
Voltage Range 81-145 VAC / 162-280 VAC
Frequency Range 60/50 Hz (auto sensing)
Output
AC Voltage Regulation (Batt. Mode) ±10%
Frequency Range (Batt. Mode) 60Hz or 50Hz ± 1Hz
Transfer Time Typical 2-6 ms
Waveform (Batt. Mode) Simulated Sine Wave
Battery
Battery Type & Number 12V 4.5 Ah×1 12V/7 Ah×1 12V 9Ah×1
Typical Recharge Time 4-6 hours up to 90% capacity
Indicators
AC Mode Green lighting
Battery Mode Green flashing
Alarm
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 second
Fault Continuously sounding
Protection
Full Protection Overload, discharge, and overcharge protection
Physical
Dimension, D × W × H (mm) 279×101×142
Net Weight (kgs) 3.55 4.25 4.9
Environment
Humidity 0-90% RH @ 0-40℃ (non-condensing)
Noise Level Less than 40dB

* Product specifications are subject to change without further notice

MCTA Series Technical Parameters

MODEL MCTA 1000VA MCTA 1500VA MCTA 2000VA
Capacity 1000VA/600W 1500VA/900W 2000VA/1200W
Input
Voltage 110/120 VAC or 220/230/240 VAC
Voltage Range 81-145 VAC / 162-290 VAC
Frequency Range 60/50 Hz (auto sensing)
Output
Output Voltage 110/120 VAC or 220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ±10%
Frequency Range (Batt. Mode) 60 Hz or 50 Hz ± 1 Hz
Transfer Time Typical 2-6 ms, 10ms max.
Waveform (Batt. Mode) Simulated Sine Wave
Battery
Battery Type & Number 12V/7 AH×2 12V/9 AH×2 12V/9 AH×2
Typical Recharge Time 4-6 hours recover to 90% capacity
Indicators
AC Mode Green lighting The right green LED lighting & the 2nd to 5th green LEDs gradually lighting indicating load level
Battery Mode Yellow flashing The right green LED flashing & the 2nd to 5th green gradually lighting indicating battery capacity
Fault Red lighting Red LED lighting
Protection
Full Protection Overload, discharge, and overcharge protection
Alarm
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 second
Battery Replacement Alarm Sounding every 2 seconds
Fault Continuously sounding
Physical
Dimension, D*W*H (mm) 350×146×160 397×146×205
Net Weight (kgs) 8.0 11.1 11.5
Operating Environment
Humidity 0-90 % RH @ 0-40℃ (non-condensing)
Noise Level Less than 40dB
Management
Optional USB/RS-232 Port Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC

* Product specifications are subject to change without further notice

Frequently Asked Questions (FAQ)

Q1: What is the main difference between the MCEX and MCTA UPS series?

A: The MCEX series is compact, ranging from 400VA to 800VA, making it ideal for personal PCs and small workstations. The MCTA series offers higher capacities from 1000VA to 2000VA, advanced LED indicators for load/battery status, and optional communication management ports.

Q2: How long does it take to recharge the UPS battery?

A: Both the MCEX and MCTA series feature efficient charging systems, typically recovering up to 90% battery capacity within 4 to 6 hours.

Q3: What does the Boost and Buck AVR function do?

A: Boost and Buck Automatic Voltage Regulation (AVR) stabilizes incoming AC power by stepping up low voltage or stepping down high voltage without switching to battery power, thereby prolonging battery life.

Q4: Does the UPS restart automatically when mains power returns?

A: Yes, both models support automatic restart while AC power is recovering, ensuring connected equipment regains operational status without manual intervention.

Q5: Can the UPS be powered on when there is no AC utility power?

A: Yes, with the built-in "Cold Start" function, the UPS can be turned on directly using battery power during a blackout or when utility power is unavailable.

Q6: What operating systems are supported by the optional management software?

A: The optional communication port supports monitoring on various platforms, including Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC OS.