Pre-engineered for secondary substations (Ortsnetzstationen), industrial feed-in switchgear, and renewable interconnects according to German technical connection rules (TAR).
ODM XGN15-24 Medium Voltage Switchgear SF6 Insulated RMU for German Distribution
Technical Specification & Quote
XGN15-12 Metal-Clad Fixed-Type RMU Switchgear Cubicle for DIN Transformer Substations
Technical Specification & Quote
OEM SafeRing-40.5 Gas Insulated Ring Main Unit (RMU) for German Wind & PV Parks
Technical Specification & Quote
SafeRing-12 Fully Insulated Compact Ring Switchgear for Urban Municipal Distribution
Technical Specification & QuoteNavigating the transformation of the German electricity grid: Decarbonization, regulatory compliance under VDE-AR-N 4110, and the phase-out of SF6 gases.
Executive Summary: Germany's federal climate mandates require greenhouse gas neutrality by 2045. As coal and nuclear baseloads are retired, the medium-voltage (Mittelspannung 10kV–36kV) network faces unprecedented multidirectional load profiles driven by decentralized utility-scale photovoltaics, onshore wind farms, industrial heat pumps, and multi-megawatt EV charging parks. Ring Main Units (RMUs) are no longer passive switching cubicles; they have become intelligent, tele-controlled, sensor-rich nodes operating under stringent DIN EN / IEC performance benchmarks.
The German energy landscape is undergoing the most profound structural realignment in modern history. The accelerated deployment of decentralized generation, characterized by the Erneuerbare-Energien-Gesetz (EEG 2023), demands the integration of hundreds of gigawatts of distributed solar PV and onshore wind into distribution system operator (DSO / VNB) networks such as Westnetz, E.DIS, Netze BW, and Bayernwerk. Over 80% of all renewable feed-in power connects directly at the medium-voltage or low-voltage level.
Consequently, secondary distribution transformer stations (Kompaktstationen / Ortsnetzstationen) require Ring Main Units with elevated short-circuit breaking capabilities, robust thermal endurance, and integrated remote terminal units (RTUs) for telecontrol and automated fault isolation (AFI). Distribution network operators face severe constraints: urban underground real estate is scarce, requiring ultra-compact switchgear footprints, while legacy European Tier-1 switchgear manufacturers face unprecedented delivery bottlenecks—frequently quoting 50 to 75 weeks lead times.
Procuring medium-voltage switchgear for German installations necessitates unwavering adherence to local standards and European legislative frameworks. The Technical Connection Rules for Medium Voltage (VDE-AR-N 4110: TAR Mittelspannung) govern all grid connections from 1 kV up to 60 kV. Ring Main Units installed at customer transfer substations (Übergabestationen) must integrate precise current/voltage sensing for directional reactive power compensation, fault ride-through (FRT) monitoring, and decoupling protection.
Simultaneously, the European Union's revised F-Gas Regulation (Regulation (EU) 2024/573) imposes strict phase-out deadlines for sulfur hexafluoride (SF6)—a potent greenhouse gas with a global warming potential (GWP) of 24,300. Starting in 2026 for new installations up to 24 kV and transitioning by 2030 for units up to 52 kV, utilities and EPC contractors are transitioning to eco-friendly gas alternatives (synthetic dry air, CO2-based gas mixtures) or Solid-Insulated Switchgear (SIS). Mingri Electric supplies both certified hermetic SF6 GIS units for existing maintenance scopes and next-generation Solid-Insulated (GXGN-12) and Eco-Gas (HBXGN-12(F)) units that eliminate SF6 emissions entirely.
Equipped with calibrated current/voltage sensor inputs (LPCT/LPVT) and integrated RTU interfaces supporting IEC 60870-5-104 and IEC 61850 protocols for seamless DSO dispatch integration.
Zero-fluorinated solutions utilizing vacuum interruption embedded in hydrophobic cycloaliphatic epoxy resin (Solid Insulated) and Clean Air options achieving GWP < 1.
Full internal arc classified containment up to 20 kA for 1.0 second, directing catastrophic arc flash exhaust gasses down through decompression ducts away from technical operators.
Historically, German public utilities (Stadtwerke) and industrial clients relied exclusively on domestic or European conglomerates. However, the modern geopolitical and supply-chain reality has exposed acute vulnerabilities: inflated capital expenditure, rigid customization frameworks, and lead times extending past 14 months.
As an advanced Chinese manufacturer based in Yueqing's premier electrical engineering cluster, Mingri Electric bridges the gap between premium DIN EN / IEC quality standards and flexible, rapid-deployment manufacturing:
Cross-reference technical parameters across gas, air, and solid dielectric insulation topologies compliant with DIN EN 62271-200 and DIN EN 62271-100.
| Parameter / Technical Characteristic | SafeRing / RM6 Series (SF6 GIS) | GXGN-12 Series (Solid Insulated) | HBXGN-12(F) (Eco-Gas / Clean Air) | SM6 Series (Modular AIS) |
|---|---|---|---|---|
| Rated Voltage (Ur) | 12 kV / 24 kV / 40.5 kV | 12 kV / 24 kV | 12 kV | 12 kV / 24 kV |
| Rated Current (Ir) Busbar | 630 A / 1250 A | 630 A / 1250 A | 630 A / 1250 A | 630 A / 1250 A |
| Short-Time Withstand (Ik / tk) | 20 kA / 25 kA (3s) | 20 kA / 25 kA (3s) | 20 kA / 25 kA (3s) | 16 kA / 20 kA (1s / 3s) |
| Internal Arc Classification (IAC) | AFL / AFLR 20 kA 1s | AFLR 20 kA 1s | AFLR 20 kA 1s | AFL 16 kA / 20 kA 1s |
| Insulation Medium & GWP | SF6 Gas (GWP = 24,300) | Epoxy / Silicone Resin (GWP = 0) | Technical Air / N2 Mix (GWP < 1) | Ambient Atmospheric Air |
| Degree of Protection (Gas Tank / Enclosure) | IP67 (Tank) / IP4X (Cabinet) | IP67 (Pole Units) / IP4X | IP67 (Tank) / IP4X | IP3X / IP4X |
| Earthing System Suitability | Resonant / Low-Resistance Grounded | Resonant / Petersen Coil Grounded | Resonant Grounded Networks | Solidly / Resonant Grounded |
| Primary German Applications | Compact Ortsnetzstationen, Wind Turbines | Flood-prone, Eco-Sensitive Zones, F-Gas Zero | Urban Stadtwerke, Green Building Leed | Industrial Distribution, Indoor Substation |
The rollout of high-power charging (HPC) plazas delivering up to 400 kW per dispenser requires dedicated 20 kV transfer substations capable of handling intense dynamic load peaks. Mingri Electric’s SafeRing and RM6 switchgear combinations (featuring Circuit Breaker "V" units with microprocessor-based protection relays) ensure rapid fault clearance without disrupting upstream utility feeders, enclosed within acoustically insulated walk-in compact stations.
Utility-scale PV installations in Brandenburg, Bavaria, and Mecklenburg-Vorpommern require rugged 36 kV/40.5 kV Ring Main Units directly coupled to central inverter stations. Operating under extreme ambient temperature swings and elevated humidity, our SafeRing-40.5 sealed stainless steel tanks protect high-voltage components from dust, condensation, and corrosion throughout the system's 30-year design life.
Continuous process manufacturing requires dual-infeed Ring Main Units with fast Automatic Transfer Switching (ATS). The XGN15 and SM6 modular series provide flexible busbar extensions, motorized switch-disconnectors, and comprehensive interlocking systems that eliminate operator hazard during planned maintenance or emergency changeovers.
Full-spectrum secondary equipment: Solid-insulated units, eco-gas switchgear, resonance controllers, low-voltage switchboards, and DC circuit breakers engineered for European projects.
HBXGN-12(F) Environment-Friendly Gas Insulated Metal Enclosed Switchgear for Germany
Technical Specification & Quote
ODM GXGN-12 Solid-Insulated Fully Enclosed Ring Main Unit for Harsh Environments
Technical Specification & Quote
MRXH-10 Arc Suppression & Resonance Elimination Cabinet for Resonant Grids
Technical Specification & Quote
SM6 Modular Air-Insulated Medium Voltage Ring Main Unit (RMU) for Commercial Sites
Technical Specification & Quote
ODM RM6 Fully Enclosed Gas-Insulated Ring Network Switchgear for Distribution Utilities
Technical Specification & Quote
GCK Low Voltage Withdrawable Switchgear Panel for Industrial Infrastructure & Plants
Technical Specification & Quote
SJKM5DC DC Molded Case Circuit Breaker for Solar PV & Battery Storage Applications
Technical Specification & Quote
Three-Phase Current-Limiting Protector 80/125A Intelligent Safety Monitoring Device
Technical Specification & QuoteClear, engineering-driven answers addressing grid compliance, type-test validations, lead times, and customization capabilities.
Yes. All Mingri Electric medium-voltage RMU products are designed and routine-tested in strict compliance with DIN EN 62271-200, DIN EN 62271-1, and DIN EN 62271-102. Furthermore, our protection and automation interfaces support electronic instrument transformers (LPCT/LPVT) and multi-function numerical protection relays that satisfy the grid connection criteria mandated by VDE-AR-N 4110 (TAR Mittelspannung).
We offer a dual-track strategy. For projects maintaining existing infrastructure, we deliver ultra-low leakage hermetic SF6 GIS units (<0.1% annual leakage rate). For new greenfield projects adhering to zero-F-gas guidelines, we provide our GXGN-12 Solid Insulated Switchgear (SIS) and HBXGN-12(F) Eco-Gas Switchgear, which completely eliminate fluorinated greenhouse gases while retaining compact dimensional footprints.
Absolutely. Our core medium-voltage switchgear architectures hold comprehensive type test certifications issued by accredited ILAC-MRA member testing laboratories (including CNAS-accredited national high-voltage testing centers), covering short-time withstand current, temperature rise limits, mechanical endurance (M2 class), and internal arc classification (IAC AFLR 20kA 1s). Complete dossiers are provided during technical evaluation.
German medium-voltage grids predominantly operate with resonant grounding (Erdschlusskompensation). Our switchgear is specifically engineered with enhanced phase-to-earth insulation withstand voltages (up to 42 kV power frequency withstand across 10/20 kV nominal networks) and accommodates directional earth-fault detection relays (e.g., transient wattmetric or qu-methods) to rapidly isolate single phase-to-ground faults without flashovers.
We engineer standard and non-standard configurations including CCF (2 Load Break Switches + 1 Fuse-switch combination), CCC (3 Load Break Switches), CCV (2 Switches + 1 Vacuum Circuit Breaker), and multi-way setups (e.g., CCCV, CCVV) up to 6 functions per monoblock tank, along with modular external busbar extension links for future substation expansion.
While standard European suppliers require 40 to 70 weeks, Mingri Electric delivers customized RMUs within 6 to 10 weeks ex-works. Sea freight to the Ports of Hamburg, Bremerhaven, or Rotterdam typically requires 28 to 35 days, with CIF/DAP customs clearance support available through our European freight forwarding partners.
Whether configuring customer substations (Übergabestationen), integrating 20kV solar generation, or transitioning to SF6-free switchgear, our electrical engineering team provides single-line diagram (SLD) reviews, tailored BIM drawings, and commercial quotations within 24 hours.
Send Inquiry Now