High-Quality JBK5 Series Machine Tool Control Transformer Factories, Companies

The JBK5 series machine tool control transformers, based on the JBK3 series, feature an optimized terminal structure integrated with the bobbin, achieving IP2LX protection against accidental contact. They use domestic IT crimp terminals for higher wiring density. Argon arc welding connects silicon steel sheets and the base plate, forming a compact structure. The one-piece base plate ensures precise mounting, while corrosion-resistant alloy enhances earthing reliability. Compliant with VDE0550, IEC204-1, EC439, JB5555, and GB5226, they are interchangeable with foreign products. Suitable for AC 50–90Hz, input ≤500V, output ≤220V, they power electrical controls, work lights, and signal lights for industrial machinery.

Product Description

Type & Meaning

JB5 Series-4
1 Machine Tool Control Transformer
2 Design Sequence Number
3 Rated Capacity (VA)
4 Tropical Product Code:
- Humid Tropical (TH)
- Dry Tropical (TA)

Product Overview

The JBK5 series machine tool control transformers are developed on the basis of the JBK3 series, with an optimized advanced terminal structure that integrates the terminals with the bobbin, raising the protection degree to IP2LX to prevent accidental contact with live circuits. Domestic IT crimp terminals are adopted, allowing a higher wiring density.

The connections between silicon steel sheets, and between the silicon steel sheets and the base plate, are all made using argon arc welding, forming a compact, integrated structure. In particular, the one-piece formed base plate ensures more precise mounting dimensions than the JBK3 series; made of high-quality corrosion-resistant alloy, it greatly improves the reliability of earthing performance and overall product quality. The product complies with international and national standards including VDE0550, IEC204-1, EC439, JB5555, and GB5226, and is interchangeable with foreign products.

The JBK5 series machine tool control transformers are suitable for AC 50~90Hz, with an input voltage not exceeding 500V and an output rated voltage not exceeding 220V. They serve as the general electrical control power supply, as well as the power supply for working lights and signal lights, for mechanical equipment in various industries.

Product Display

Outline and Installation Dimensions

Outline and Mounting Dimension Drawings 1, 2 and Table 1 of the Transformer

Model Overall Dimensions Mounting Dimensions Mounting Holes (K) Fmax Remarks
Bmax Dmax Emax A C
JBK5-40/63VA 78 72 96 56±0.15 46±0.125 4.6 1.5 -
JBK5-100VA 85 88 96 64±0.15 62±0.15 4.6 1.5 -
JBK5-160VA 96 92 106 84±0.175 73.5±0.5 5.5 1.5 -
JBK5-250VA 96 100 106 84±0.175 85±0.175 5.8 1.5 -
JBK5-400VA 120 100 122 93±0.175 84±0.175 5.8 2 -
JBK5-630VA 150 114 140 125±0.2 92±0.175 7 2 -
JBK5-800VA 150 125 142 125±0.2 105±0.2 7 2 -
JBK5-1000VA 160 195 142 140±0.2 158±0.2 7 3 -
JBK5-1000VA 168 130 155 138±0.2 105±0.2 9 2 Horizontal Type
JBK5-1600VA 184 225 145 155±0.2 180±0.2 7 3 Vertical Type
JBK5-1600VA 168 140 155 138±0.2 116±0.2 9 2 Horizontal Type
JBK5-2500VA 250 200 152 165±0.2 210±0.23 7 4 Vertical Type

Technical Parameters

The main technical parameters of the transformer are listed in Table 2

Model Power (%) Signal Winding (%) Control Winding (%) Signal Winding (%) Control Winding (%) Rated Input Voltage (V) Rated Output Voltage (V) Remarks
JBK5-40VA 80 5<Um≤5
10<Um≤10
95%~105% UH 6 or 12 1.1Um AC380 ±5%

AC220 ±5%
AC220
(127)/110 -- Control

48/35/24 -- Lighting or Control

12/6 -- Signal
The capacity allocation of each winding can be manufactured according to user requirements
JBK5-63VA
JBK5-100VA
JBK5-160VA 85
JBK5-250VA
JBK5-400VA
JBK5-630VA
JBK5-800VA -
JBK5-1000VA
JBK5-1600VA 90 4.5<Um≤6
9<Um≤12
JBK5-2500VA

Frequently Asked Questions (FAQ)

What are the primary applications of the JBK5 control transformer?
The JBK5 series is mainly used in industrial machinery and mechanical equipment as a general electrical control power supply, as well as an illumination and indicator power supply for working lights and signal lights.
What are the key improvements of JBK5 compared to the JBK3 series?
The JBK5 integrates terminals with the bobbin to achieve an IP2LX protection rating against accidental contact, utilizes argon arc welding for the core structure, and features a one-piece formed base plate that enhances dimensional precision and earthing reliability.
What input and output voltage ranges can the JBK5 transformer handle?
It is designed for AC 50~90Hz systems, supporting an input voltage up to 500V (such as standard AC 380V or AC 220V) and a rated output voltage up to 220V, with steps down to 110V, 48V, 24V, 12V, or 6V.
Can the capacity allocation of individual windings be customized?
Yes, the capacity allocation across the control, lighting, and signal windings can be customized and manufactured according to specific user requirements.
Which international standards does the JBK5 transformer comply with?
The series complies with international and national standards including VDE0550, IEC204-1, EC439, JB5555, and GB5226, ensuring direct interchangeability with compatible foreign equipment.
What mounting options are available for higher capacity models?
Higher capacity models, such as 1000VA and 1600VA, are available in both horizontal and vertical mounting configurations to adapt to different enclosure spaces.

Related Products