OEM HR5 Fused Disconnect Switch with Visible Contacts Supplier, Factory

The HR5 Fused Disconnect Switch delivers reliable circuit protection and isolation for industrial systems, supporting 100-630A loads at AC400-660V with AC-22B/AC-23B utilization categories. This fused disconnect switch features 10le making capacity and 8le breaking capacity under 1.05Ue voltage, ensuring robust performance with 50kA short-circuit breaking capability. Designed for heavy-duty applications, the HR5 switch operates with 0.25-0.65 power factor and handles 3-5 switching cycles per fault condition. Its fused design combines manual control and overload protection, ideal for motor circuits and power distribution panels requiring safe isolation and fault interruption.

Product Description

Type and Meaning

HR3-10 Type Designation Structure
Position Designation Meaning
1 Fuse-disconnector
2 Design Code
3 Rated operational current: 100A, 200A, 400A, 630A
4 Number of poles: 2-pole, 3-pole
5 "0" indicates the non-fused signal device type (used with a fuse link equipped with a fuse indicator).
"1" indicates the fused signal device type (used with a fuse link equipped with a tripping mechanism).

Product Display

Technical Parameters

Rated Operational Voltage Ue (V) Conventional Heating Voltage Ue (V) Utilization Category Rated Making and Breaking Capacity Rated Short-Circuit Breaking Capacity
Make Break Operation Cycle Count Root Mean Square Current (kA) COSΦ Switching Cycles
I/Ie U/Ue COSΦ Ic/Ie Ur/Ue COSΦ
400 100 AC-23B 10 1.05 0.45 8 1.05 0.45 5 50 0.25 Once each
200 AC-23B 10 1.05 0.35 8 1.05 0.35 3 50 0.25 Once each
400 AC-23B 10 1.05 0.35 8 1.05 0.35 3 50 0.25 Once each
630 AC-23B 10 1.05 0.35 8 1.05 0.35 3 50 0.25 Once each
660 100 AC-22B 3 1.05 0.65 3 1.05 0.65 5 50 0.25 Once each
200 AC-22B 3 1.05 0.65 3 1.05 0.65 5 50 0.25 Once each
315 AC-22B 3 1.05 0.65 3 1.05 0.65 5 50 0.25 Once each
400 AC-22B 3 1.05 0.65 3 1.05 0.65 5 50 0.25 Once each

Outline and Installation Dimensions

HR3-4 Outline Dimensions Diagram
Model (Number) Dimensions (mm)
a b c d e f (Mounting Hole Pitch)
HR5-200/20 203 203 62 193 342 130
HR5-200/30 203 203 62 193 342 130
HR5-200/31 220 203 62 193 342 130
HR5-400/20 226 226 70 210 358 130
HR5-400/30 226 226 70 210 358 130
HR5-400/31 242 226 70 210 358 130
HR5-630/20 272 272 85 224 372 200
HR5-630/30 272 272 85 224 372 200
HR5-630/31 290 272 85 224 372 200

Frequently Asked Questions (FAQ)

QWhat is the main function of the HR series fuse-disconnector switch?
The switch provides isolation protection and overload/short-circuit protection in low-voltage electrical distribution systems, allowing safe manual switching and circuit disconnection.
QWhat is the operational difference between code suffix "0" and "1"?
Code suffix "0" designates a non-fused signal device type configured for fuse links with visual indicators, while "1" indicates a fused signal device type designed for fuse links with mechanical tripping mechanisms.
QWhat rated currents are available for this series?
Standard configurations support rated operational currents of 100A, 200A, 315A, 400A, and 630A across specified voltage ratings.
QWhat is the rated short-circuit breaking capacity?
The product line achieves a root mean square short-circuit breaking capacity rating of 50kA under specified test standards.
QCan these fuse-disconnectors be operated in both 2-pole and 3-pole configurations?
Yes, unit structures are manufactured in both 2-pole and 3-pole arrangements to accommodate various electrical grid setups.