The MS132-25 delivers superior motor protection for demanding industrial environments. This high-performance motor protection circuit breaker supports motors up to 15kW at 400V with a 25A adjustable current setting. Featuring Class 10 tripping and an impressive 100kA breaking capacity at 400V, it handles high fault currents safely. The device includes thermal-magnetic protection, phase loss detection, and temperature compensation across -25°C to +60°C. Its 45mm compact design fits standard DIN rails, while the visible trip indication and lockable handle enhance operational safety. Compatible with ABB contactors and soft starters for seamless system integration in automation applications.High Performance

Product Description

Type and Meaning

MS132-5
1 Series Number
MS: Thermal-magnetic trip
MO: Magnetic-only trip
2 Rated current, trip class and breaking capacity
116-32A, Class 10A (10/16/30/50kA)
132-32A, Class 10A (25/50/100kA)
450-50A, Class 10A (50kA)
451-50A, Class 20A (50kA)
495-100A, Class 10A (50kA)
496-100A, Class 20A (100kA)
497-100A, Class 10A (100kA)
3 Thermal protection setting value

Product Features

Model MS132
Thermal protection and electromagnetic protection Yes
Electromagnetic protection -
Phase failure protection Yes
Switch position… ON/OFF/TRIP
Magnetic release indication YES
Lockable handle,no accessories required YES
Isolation function Yes
Width 45mm
Rated operating current 0.16...32A
Current setting range 0.1...32A
Ambient air temperature -25...+60°C*)

Product Display

Technical Parameters

Motor Rated Power Thermal Trip Setting Range Type Short-Circuit Breaking Capacity
Icu Ice
0.03 kW 0.1…0.16A MS132-0.16 100 kA 100kA
0.06 kW 0.16…0.25A MS132-0.25 100 kA 100 kA
0.09 kW 0.25…0.4A MS132-0.4 100kA 100kA
0.18 kW 0.4…0.63A MS132-0.63 100KA 100kA
0.25 kW 0.63…1.0A MS132-1.0 100kA 100kA
0.55 kW 1.0…1.6A MS132-1.6 100kA 100 kA
0.75kW 1.6…2.5A MS132-2.5 100 kA 100kA
1.5kW 2.5…4.0A MS132-4.0 100kA 100kA
2.2 kW 4.0…6.3A MS132-6.3 100 kA 100kA
4.0 kW 6.3...10 A MS132-10 100 kA 100kA
5.5 kW 8…12A MS132-12 100kA 100KA
7.5 kW 10…16A MS132-16 / MS165-16 100 KA 100kA
7.5 kW 14...20 A MS165-20 100kA 100 kA
7.5kW 16…20 A MS132-20 100kA 100kA
11 kW 18…25A MS165-25 100 kA 75kA
11 kW 20…25A MS132-25 50 kA 50 kA
15 kW 25…32A MS132-32 50KA 25kA
15kW 23...32A MS165-32 100 KA 75 kA
22 kW 30…42A MS165-42 50 kA 25 kA
22kW 40...54 A MS165-54 50 kA 25 kA
30 kW 52…65A MS165-65 50 kA 25 kA

Outline and Installation Dimension

MS132-4 Outline and Installation Dimension

Frequently Asked Questions (FAQ)

Q: What is the primary difference between the MS and MO series?

The MS series provides comprehensive thermal-magnetic protection designed to protect against both overloads and short circuits. The MO series features magnetic-only trip protection, primarily intended for short-circuit protection when paired with external thermal overload devices.

Q: Does the MS132 circuit breaker include phase failure protection?

Yes, the MS132 manual motor starter comes standard with built-in phase failure sensitivity, ensuring safe operation and motor disconnection in the event of an unbalanced power supply or lost phase.

Q: Can the handle be locked directly without auxiliary accessories?

Yes, the MS132 series features a lockable rotary handle that can be locked directly in the OFF position using a padlock, requiring no additional locking brackets or accessories.

Q: What is the operating ambient temperature range for this series?

The device operates reliably within an ambient air temperature range of -25°C to +60°C, providing compensated thermal protection across fluctuating thermal conditions.

Q: What is the standard module width of the MS132 unit?

The MS132 features an ultra-compact modular width of 45 mm, enabling space-saving installation on standard DIN rails within industrial control panels.