OEM FK(R)N12-12 High Voltage Air Load Breaker Fuse Switch Supplier, Companies

The FKN12-12D load switch and FKRN12-12D switch-fuse combination are designed for 12kV three-phase distribution systems, suitable for transformer, cable, and line control. With rated currents of 630A (FKN) and 125A (FKRN), they feature high insulation, spring-operated mechanisms, and reliable arc extinction in bell-shaped covers. Compact and interlocked, they offer 2000 mechanical operations and withstand harsh environments (–25°C to +40°C, ≤2000m). Ideal for substations and ring networks, these GB/T and IEC-compliant switches ensure safe load switching, overload protection, and short-circuit interruption in urban and industrial applications.

Product Description

Type & Meaning

CJX2-D-4 Model Breakdown
Code Specification Meaning
1Rated short-time withstand current (kA)
2Rated current (A)
3Spring mechanism
4Earthing switch (optional)
5Rated voltage (kV)
6Design No.
7Indoor
8Air medium
9Load switch
CJX2-D-4 Model Designation
Code Specification Meaning
1Rated short-circuit breaking current (kA)
2Rated current of the maximum fuse equipped (A)
3Spring mechanism
4Earthing switch (optional)
5Rated voltage (kV)
6Design No.
7Indoor
8With fuse holder
9Air medium
10Load switch

Ambient Conditions

  • Ambient temperature: -25℃ ~ +40℃
  • Altitude: ≤ 2000m
  • Ambient humidity: Daily mean relative humidity ≤ 95%, monthly mean ≤ 90%
  • Seismic intensity: ≤ Ms8
  • Anti-fouling level: Class Ⅱ
  • Operating environment: Free of flammable or explosive hazards, chemical corrosive gases, water vapor, and violent vibration.
Note: Please negotiate with the manufacturer if environmental conditions exceed the above parameters.

Product Display

Technical Parameters

☆ Technical parameters of FKN12-12D series switch and FKRN12-12D series switch-fuse combinations are shown in Table 1

No. Item Unit FKN12-12D FKRN12-12D
1 Rated voltage kV 12 12
2 Rated frequency Hz 50 50
3 Rated current A 630 125
4 Rated insulation level 1min power-frequency withstand voltage To-ground, phase-to-phase kV 42 42
Isolating distance 48 48
Lightning impulse withstand voltage (peak) To-ground, phase-to-phase 75 75
Isolating distance 85 85
5 Rated short-time withstand current Load switch kA 25 -
Earthing switch 20 -
6 Rated short-circuit duration Load switch S 4 -
Earthing switch 2 -
7 Rated short-circuit making current (peak) kA 50 -
8 Rated breaking current Active load breaking current A 630 -
Closed loop breaking current 630 -
Cable charging current 10 -
Breaking capacity of no-load transformer kVA 1250 -
9 Rated short-circuit breaking current (current-limit fuse) kA - 31.5
10 Rated transfer current A - 1200
11 Mechanical endurance times 2000 2000

☆ Mechanical properties are shown in Table 2

No. Item Unit Parameter
1Isolating distancemm≥175
2Phase-to-phase central distance210±2
3Phase-to-phase air clearance≥125
4Travel210±4
5Overtravel≥40
6Out of simultaneity of three-phase closingms≤10
7Out of simultaneity of three-phase opening≤15
8Inherent opening time of shunt release40~65
9Main circuit resistanceμΩ≤130

☆ For the current-limiting fuse in switch-fuse combinations, the rated current of the fuse-link is selected based on the transformer capacity (Table 3):

Transformer capacity (kVA) 100 125 160 200 250 315 400 500 630 750/800 1000 1250
Rated current of fuse (A) 10 12.5 16 20 25 31.5 40 50 63 80 100 125

Outline and Installation Dimensions

Outline and Installation Dimensions Drawing

Frequently Asked Questions

1. What is the difference between the FKN12-12D and FKRN12-12D models?
The FKN12-12D is a high-voltage air load break switch, whereas the FKRN12-12D is equipped with an integrated fuse base to accommodate current-limiting fuses, providing enhanced short-circuit breaking capability up to 31.5 kA.
2. What are the standard ambient operating conditions for this switchgear?
Standard operation requires an ambient temperature between -25°C and +40°C, an altitude not exceeding 2000 meters, relative humidity averaging ≤95% daily (≤90% monthly), seismic tolerance up to Ms8, and an environment free of corrosive gases, water vapor, or explosive hazards.
3. What is the rated mechanical endurance of the switch?
Both the FKN12-12D switch and FKRN12-12D fuse-switch combination have a tested mechanical endurance rating of 2,000 operation cycles.
4. Which fuse rating is recommended for a 500 kVA transformer?
According to the technical selection table (Table 3), a 50 A rated current-limiting fuse link is recommended for a 500 kVA transformer application.
5. Can this equipment be installed in environments higher than 2000m above sea level?
Standard configurations are rated for altitudes up to 2000m. For higher altitudes or specialized environmental requirements, technical parameters must be negotiated directly with the manufacturer for custom adaptation.
6. What is the insulation performance level for this 12 kV equipment?
It features a 1-minute power-frequency withstand voltage of 42 kV (phase-to-phase and to-ground) / 48 kV (isolating distance), and a lightning impulse withstand peak voltage of 75 kV (to-ground/phase-to-phase) / 85 kV (isolating distance).