China CJX2-F Series AC Contactor for Motor Control Suppliers, Manufacturer

CJX2-F series AC contactors operate in 50/60Hz circuits (40-400Hz with special coils) up to 660V, 630A. Ideal for main circuit switching, frequent motor starting/control. Models include CJX2-F115 to F630, supporting AC-3/AC-4 applications. Combine with relays, auxiliary contacts, pneumatic time-delay heads for interlocked assemblies or star-delta starters. Pair with thermal relays for complete magnetic starters. Suitable for squirrel-cage asynchronous motors, with max power up to 450W at 660V. Features high electrical/mechanical endurance for reliable industrial use.

Product Description

Application

CJX2-F series AC contactors (the following is called a contactor) are used in 50Hz or 60Hz circuits. If equipped with a special coil, they can be used in circuits with a frequency of 40-400Hz, with a voltage up to 660V and a current up to 630A. They are used for making and breaking the main circuit, as well as for frequently starting and controlling motors.

They can be combined with general electrical equipment such as various relays, which can be used to control various electrical equipment, motors, and circuits. With auxiliary contact groups, pneumatic time-delay heads, and mechanical interlocks, they can also form mechanically interlocked contactors and star-delta starters. When combined with a thermal relay, they can form a magnetic starter.

Type & Meaning

CJ X2 - F □ 1 2 3 4
1 AC contactor
2 minature
3 series code
4 rated working current

Features

With fine and compact structure, functional molding, and coordinated assembly stereoscopic layout, the contactor product with a triple, triad wiring structure is of linear motion type, and the contact features double-breaking points. A mechanical interlock mechanism is added between two contactors to form a reversible shift contactor.

Product Display

Technical Parameters

Table 1
Type CJX2-F115 CJX2-F150 CJX2-F185 CJX2-F225 CJX2-F265 CJX2-F330 CJX2-F400 CJX2-F500 CJX2-F630
Rated operational current AC-3 380V 115 150 185 225 265 330 400 500 630
660V 86 107 118 135 170 325 305 355 460
AC-4 380V 52 60 79 85 105 217 138 147 188
660V 49 61 69 82 98 118 135 145 170
controlled squirrel-cage
asynchronous motor's max
power pe(W)
AC-3 380V 55 75 90 110 132 160 200 250 335
660V 80 100 110 129 160 220 280 335 450
AC-4 380V 25 30 40 45 55 63 75 80 100
660V 45 55 63 75 90 110 129 140 160
Conventional thermal current (Ith) 200 250 275 315 350 450 500 700 1000
Vrated operational voltage (Ue) 380, 660
Rated insulation voltage (V) 660
operating frequency IEC947, GB14048
AC-3 Electrical endurance 60×10° 50×10⁴ 30×10⁴ 20×10⁴
Switching frequency 600 300
AC-4 Electrical endurance 15×10⁴ 8×10⁴ 5×10⁴
Switching frequency 150
Mechanical endurance Time 3×10⁶ 1×10⁶
Auxiliary contacts Rated heating current(Ith)A 10 -
Electrical endurance 60×10⁴ 50×10⁴ 30×10⁴ 20×10⁴

Specification of Coil

Type CJX2-09 CJX2-12 CJX2-18 CJX2-25 CJX2-32 CJX2-40 CJX2-50 CJX2-63 CJX2-80 CJX2-95
Close voltage 50/60Hz(V) (0.85~1.1)Us
Release voltage 50/60Hz(V) (0.2~0.75)Us
Coil power 50Hz Closing(VA) 70 70 70 110 110 200 200 200 200 200
Closed(VA) 8 8 8 11 11 20 20 20 20 20
60Hz Closing(VA) 80 80 80 115 115 200 200 200 200 200
Closed(VA) 8 8 8 11 11 20 20 20 200 200
Consumption(W) 1.8-2.7 1.8-2.7 1.8-2.7 3~4 3~4 6~10 6~10 6~10 6~10 6~10

Outline and Installation Dimension

CJX2-F115-F330 outline and installation dimensions are shown in Figure 1 and Table 2.

CJX2-D-4
Table 2
Type a max b max b1 max c max G L P Q Q1 S X Z Y f max k max
CJX2-F115 165 164 137 167 80±0.8 108 37 29.5 60 15 57 26.5 M6×15 133 40
CJX2-F150 165 172 137 167 80±0.8 108 40 26.5 57.5 20 57 26.5 M6×20 133 40
CJX2-F185 171 176 137 181 80±0.8 114 40 30 60 20 59.5 29 M6×20 133 40
CJX2-F225 171 199 137 181 80±0.8 114 48 22 52 25 59.5 29 M6×30 133 40
CJX2-F265 204 205 145 210 96±1.1 143 48 39 66.5 25 61 44.5 M6×30 147 50
CJX2-F330 209 209 145 216 96±1.1 148 48 36 74 25 67 50.5 M6×30 147 60

Note: fmin represents the required space for coil replacement, Kmin represents the minimum electrical clearance, and the remaining text refers to the clamp plate wiring.

CJX2-F400-F500 outline and installation dimensions are shown in Figure 2 and Table 3 and Table 4.

CJX2-D-4
Table 3 & Table 4
Type a max b max c max f max k max S J L P Q Q1
CJX2-F400 213 206 213 119 70 25 19.5 14.5 48 43 74
CJX2-F500 233 238 226 141 70 30 39.5 146 55 46 77
Type Size No. Nominal Value max min
CJX2-F400 G 80 102 66
G1 170 192 156
CJX2-F500 G 80 120 66
G1 170 210 156

CJX2-F630 outline and installation dimensions are shown in Figure 3 and Table 5.

CJX2-D-4
Table 5
Size No. Nominal Value max min
G 180 195 100

Frequently Asked Questions (FAQ)

What circuit frequencies are supported by CJX2-F series AC contactors?

They are designed for standard 50Hz or 60Hz circuits. When equipped with a special coil, they can operate within frequencies ranging from 40Hz to 400Hz.

What are the maximum rated current and operational voltage capabilities?

The CJX2-F series can accommodate operational voltages up to 660V and rated operational currents up to 630A.

Can CJX2-F contactors be used to build star-delta starters or reversible units?

Yes, by combining auxiliary contact blocks, pneumatic delay heads, and mechanical interlocks, they can be configured into star-delta starters, reversible contactors, or magnetic starters with thermal overload relays.

What contact structure is utilized in these contactors?

They feature a linear motion type structure with a triple/triad wiring design and double-breaking point contacts for enhanced switching reliability.

What do the dimensions fmin and Kmin refer to in the technical drawings?

In the installation specification tables, fmin denotes the required space for replacement of the coil, while Kmin refers to the minimum necessary electrical clearance distance.