Engineered to address high fault-level stresses and tropical monsoonal humidity across southern Vietnam, our primary line of indoor medium and high-voltage vacuum circuit breakers delivers uncompromised arc quenching and dielectric resilience.
Ho Chi Minh City (HCMC) stands as Vietnam’s paramount economic engine, generating roughly a quarter of the national GDP and housing high-load-density zones from the bustling Thu Duc Innovation District to expansive export processing facilities in Tan Binh, Linh Trung, and Tan Thuan. Rapid modernization under Vietnam's National Power Development Plan VIII (PDP8) has accelerated the transition toward digitalized 24 kV distribution networks, smart urban substations, and dedicated industrial microgrids.
HCMC’s equatorial monsoon climate features sustained ambient humidity averaging 75% to 95% and temperatures exceeding 38°C in switchgear rooms. Our VCBs utilize embedded pole solid epoxy resin casting to prevent moisture condensation, partial discharge, and tracking across air gaps under high vapor saturation.
Unlike traditional 10 kV and 35 kV tiers in other regions, Southern Power Corporation (EVNSPC) and Ho Chi Minh City Power Corporation (EVNHCMC) deploy standardized 22 kV and 24 kV architectures. All switchgear components must deliver BIL withstand voltages up to 125 kV impulse and 50 kV power frequency.
As mega-datacenters, semiconductor packaging hubs, and precision CNC manufacturing centers proliferate near Saigon Hi-Tech Park (SHTP), network interconnection density surges. Interruption ratings of 25 kA, 31.5 kA, and up to 40 kA ensure fast clearance without cascading arc flash events.
At the core of our high-voltage vacuum circuit breakers lies an ultra-clean vacuum interrupter envelope maintaining pressures below 10-5 Pa. By leveraging axial magnetic field (AMF) and transverse magnetic field (TMF) contact geometries, diffuse vacuum arcs are maintained during fault clearance, safeguarding contact material against heavy micro-welding and pitting.
| Technical Specification | 12 kV System Class (Indoor) | 24 kV EVNHCMC Standard | 40.5 kV Industrial / Wind Step-Up |
|---|---|---|---|
| Rated Continuous Current | 630 A / 1250 A / 2500 A / 3150 A | 630 A / 1250 A / 2000 A / 2500 A | 1250 A / 1600 A / 2000 A |
| Rated Short-Circuit Breaking (Isc) | 25 kA / 31.5 kA / 40 kA | 25 kA / 31.5 kA | 25 kA / 31.5 kA |
| Lightning Impulse Withstand (BIL) | 75 kV (Peak) | 125 kV (Peak) | 185 kV / 200 kV (Peak) |
| Power Frequency Withstand (1 min) | 42 kV | 50 kV / 65 kV | 95 kV |
| Operating Sequence | O - 0.3s - CO - 180s - CO | O - 0.3s - CO - 180s - CO | O - 0.3s - CO - 180s - CO |
| Mechanical Endurance Class | Class M2 (10,000 to 30,000 ops) | Class M2 (Modular Spring / Magnetic) | Class M2 (Heavy Industrial Spring) |
| Standards Conformity | IEC 62271-100 / TCVN 8096-100 | IEC 62271-100 / EVN Guidelines | IEC 62271-100 / GB 1984 |
From primary 110 kV/24 kV utility transformer substations to Tier III+ hyperscale data centers, our VCB installations protect mission-critical operations where power disturbances represent catastrophic financial loss.
Semiconductor assembly and automated cleanrooms cannot tolerate millisecond-level voltage dips. Our withdrawable VS1-12/24 circuit breakers with ultra-low bouncing times (<2ms) isolate upstream transients seamlessly, safeguarding delicate wafer handling lines and micro-electronics production.
Continuous operations require N+1 and 2N switchgear redundancy. Our modular VCB units interface with digital relays and intelligent power management systems (SCADA via Modbus/IEC 61850), delivering real-time vacuum integrity status, coil temperature surveillance, and fast transfer trip switching.
Maritime atmospheric salinity along the Soai Rap River aggressively degrades traditional medium-voltage switchboards. We deliver side-mounted and embedded-pole vacuum breakers enclosed in anti-corrosive galvanic-coated enclosures designed to withstand coastal saline fog and sulfur accumulation.
Worldwide power distribution is experiencing a seismic transition: shifting away from greenhouse-heavy SF6 (sulfur hexafluoride) insulation toward vacuum interruption and clean-air or solid-dielectric topologies. For Ho Chi Minh City, this global paradigm intersects directly with stringent urban space constraints and intense rooftop solar integration.
With Europe’s F-gas regulations and global net-zero commitments impacting multinational supply chains in Vietnam (Apple, Samsung, Intel tier-1 suppliers), our pure vacuum interrupters completely eliminate greenhouse gas leakage risks and future disposal penalties.
Industrial rooftop photovoltaics across Binh Chanh and Cu Chi feed intermittent, bi-directional power back into the 22 kV feeders. Our VCB mechanisms provide instantaneous clearing times (<45ms) and withstand frequent no-load capacitive cable switching without restrike.
Every unit delivered to the HCMC territory undergoes rigorous conformity testing under IEC 62271-100 and Vietnamese TCVN 8096 criteria, including full type-test validation for temperature rise, lightning impulse insulation, and short-time withstand thermal resistance (4s rating).
Complementing our high-voltage vacuum circuit breaker series, we supply fully integrated primary switchboards, disconnectors, low-voltage drawout panels, and industrial transformers engineered for turn-key reliability across Vietnamese infrastructure projects.
As Ho Chi Minh City elevates its utility automation targets under EVN’s digital transformation roadmap, passive mechanical circuit breakers are evolving into self-diagnosing, networked cyber-physical power assets.
By algorithmically computing cumulative interrupted current (ΣIyt), the intelligent controller calculates real-time erosion of the copper-chromium (CuCr) contact alloy, projecting remaining operational life without manual chamber disassembly.
Surface acoustic wave (SAW) wireless temperature sensors affixed directly to primary tulip jaw contacts transmit real-time thermal profiles. Plant engineers detect resistance spikes caused by oxidation or loosening long before catastrophic bus thermal runaways occur.
Integrated smart terminal units (STU) link seamlessly to SCADA master stations via GOOSE and MMS protocols, enabling rapid multi-feeder selective interlocking and sub-cycle fault isolation without complex cross-cabinet hardwiring.
Direct answers to technical, commercial, and operational questions regarding medium-voltage vacuum circuit breakers deployed across Ho Chi Minh City and southern regional provinces.
Under EVNHCMC and national grid regulations, distribution lines nominally operate at 22 kV. However, equipment must be rated for the highest system voltage (Um = 24 kV) to sustain continuous network tolerances (+10%), temporary overvoltages, and lightning impulses (125 kV peak BIL) characteristic of tropical storm seasons in southern Vietnam.
Withdrawable VCBs (like the VS1 series) mount on a racking truck inside switchgear like KYN28A-24, enabling mechanical racking between connected, test, and disconnected positions with internal safety shutters. Side-mounted VCBs (such as VS1-12C) are bolted directly to the switchgear frame, offering an ultra-compact footprint favored in fixed-mount Ring Main Units (RMU) and packaged outdoor substations where space is constrained.
Traditional assembled poles expose the ceramic or glass vacuum interrupter to circulating air, where continuous 90%+ relative humidity and dust can cause surface tracking and dielectric breakdown. Embedded poles use automatic pressure gelation (APG) epoxy technology to cast the interrupter and terminal connectors into a single monolithic resin block, making the electrical insulation impervious to ambient moisture, dust, and corrosive airborne contaminants.
Yes. Our engineering division provides customized interlocking dimensioning, secondary pin-terminal adaptation, and chassis guide-rail matching. We frequently supply retrofit kits to replace aged, oil-immersed or legacy air-break circuit breakers inside older switchboards across industrial parks in Binh Duong and Dong Nai without replacing entire switchgear line-ups.
Shipments are accompanied by routine factory test reports (including mechanical timing, power-frequency dielectric withstand, main loop contact resistance, and vacuum integrity tests), full type-test certificates from internationally recognized laboratories (such as KEMA, ASTA, or national CNAS-accredited centers), Certificate of Origin (Form E or standard CO), and warranty certificates.
Standard parameter 12 kV and 24 kV units (630A to 1250A, 25kA/31.5kA) are maintained in regional buffer stocks with dispatch within 7 to 10 working days. Custom engineering configurations—such as specialized auxiliary switch combinations, under-voltage release schemes, or heavy 3150A/40kA ratings—typically ship within 3 to 4 weeks direct to Cat Lai Port or Tan Son Nhat air cargo terminals.
Whether designing a new 24 kV distribution network for an industrial manufacturing park or modernizing high-density commercial switchrooms in Thu Duc City, our senior electrical engineering group provides comprehensive design, quotation, and compliance validation.