Introducing the SJKM1 Moulded Case Circuit Breaker (MCCB), a top-tier solution for AC 50/60Hz power systems operating up to 690V and 1250A. As a reliable choice among China suppliers, this MCCB offers exceptional protection against overloads, short circuits, and undervoltage, making it perfect for distribution networks. With configurations available for frame sizes up to 400A, it is also capable of safeguarding motors effectively. Crafted in compliance with IEC 60947-2 and GB14048.2 standards, the SJKM1 MCCB ensures safe and efficient power distribution alongside optimal equipment protection. Designed for durability, it supports infrequent switching and motor starts, making it an ideal fit for industrial and commercial applications sourced from trusted factories in China.

,

Product Description

Type Designation

SJKM1 Moulded Case Circuit Breaker Designation
No. Designation Details
①Manufacturer Code
②Molded Case Circuit Breaker Code
③Design Code
④Frame Size
⑤Short-Circuit Breaking Capacity Level 4
⑥Operation method 3
⑦Number of Poles 2
⑧Trip Unit Method & File Code
⑨Function Code 1
⑩Type code(See Table 1 for N-pole of four-pole,no code for three-pole)
Notes:

1. There is no code for distribution circuit breakers; for motor-protection circuit breakers, use 2 to represent.

2. Number of poles: 2 for two-pole; 3 for three-pole; 4 for four-pole.

3. For handle-direct operation: use D to represent for power-distribution use, and use Z to represent for conversion-locking use.

4. For economy type: represent with E; for standard type: represent with M; for higher-reliability type: represent with H; for high-breaking type: represent with L.

Product Display

SJKM1 Moulded Case Circuit Breaker View 1
SJKM1 Moulded Case Circuit Breaker View 2
SJKM1 Moulded Case Circuit Breaker View 3
SJKM1 Moulded Case Circuit Breaker View 4

N - Pole Type Code

Type Code Description
Type ANo over-current release element is installed on the N-pole, and the N-pole is always connected, and does not close and open together with the other three poles.
Type BNo over-current release element is installed on the N-pole, and the N-pole closes and opens together with the other three poles (the N-pole closes first and opens later).
Type CAn over-current release element is installed on the N-pole, and the N-pole closes and opens together with the other three poles (the N-pole closes first and opens later).
Type DAn over-current release element is installed on the N-pole, and the N-pole is always connected, and does not close and open together with the other three poles.

Release Modes and Accessory Codes

Accessory Name Without Accessory Alarm Contact Shunt Release Auxiliary Contact Under-voltage Release Shunt Release Auxiliary Contact Two-group Auxiliary Contacts Shunt Release Under-voltage Release Auxiliary Contact Under-voltage Release
Release Mode Instantaneous Code 200208210220230240250260270
Compound Code 300208310320330340350360370

(Continued from the previous table)

Accessory Name Shunt Release Alarm Contact Auxiliary Contact Alarm Contact Under-voltage Release Alarm Contact Shunt Release Auxiliary Contact Alarm Contact Two-group Auxiliary Contact Alarm Contact Auxiliary Contact Under-voltage Release Alarm Contact
Release Mode Instantaneous Code 218228238248268278
Compound Code 318328338348268378
Notes:

1) 200 indicates the circuit breaker body with only an electromagnetic release; 300 indicates the circuit breaker body with thermal and electromagnetic releases.

2) For the two-level products SJKM1-125 and SJKM1-250, only 210, 310, 220, 320, 230, and 330 are available.

Normal Operating Conditions and Installation Conditions

◆
Ambient temperature: The circuit breaker can operate normally at an ambient temperature range of -5°C to +40°C (except for special orders).
◆
Altitude: The altitude of the installation site of the circuit breaker shall not exceed 2000m.
◆
Pollution degree: The pollution degree of the circuit breaker is Grade 3.
◆
Installation category: The installation category of the circuit breaker is Category III.
◆
Installation position: The circuit breaker can be installed horizontally, vertically, or flat, without reducing its electrical performance.

Main Parameters and Technical Performances

Circuit Breaker Model SJKM1-63 SJKM1-125 SJKM1-250 SJKM1-400 SJKM1-630 SJKM1-800 SJKM1-1250
Pole Number 34 324 324 34 34 34 34
Rated Current In (A) 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 125 100 125 140 160 180 200 225 250 225 250 315 350 400 400 500 630 630 700 800 800 1000 1250
Rated Insulation Voltage Ui (V) 690 1000 1000 1000 1000 1000 1000
Rated Impulse Withstand Voltage Uimp (V) 6000 - - - - 8000 -
Rated Working Voltage Ue (V) 400 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690
Breaking Capacity Level LM LMH LMH LMH LMH H H
Ultimate Short-Circuit Breaking Capacity Icu (kA) 400V 2550 355085 355085 5065100 5065100 100 100
690V -- --25 --25 --30 --30 - 25
Service Short-Circuit Breaking Capacity Ics (kA) 400V 1830 253550 253565 355065 355065 65 50
690V -- --15 --15 --20 --20 - 20

Appearance and Installation Dimensions

◆ Appearance and installation dimensions of the fixed-type front-connected and rear-connected wiring
SJKM1 MCCB Fixed Type Front and Rear Wiring Dimensions Diagram 1
SJKM1 MCCB Fixed Type Front and Rear Wiring Dimensions Diagram 2
◆ Appearance and installation dimensions of fixed-type front and rear wiring
Model Number Overall dimensions (mm) Mounting Dimensions (mm) Dimensions for Rear Terminal Wiring (mm)
LL1WHH1H2ab φdalb1d1H3H4
SJKM1-63L3135217688721925117425117185275
SJKM1-63M----978228--------
SJKM1-634--103-----------
SJKM1-125L-1505192866824301294.5301322265100
SJKM1-125M3---1048623--------
SJKM1-125H---------------
SJKM1-1252--65-------------
412230
SJKM1-250L-165641071088725351265.5351442470110
SJKM1-250M3165-107124.510424.5--------
SJKM1-250H---------------
SJKM1-2502--75------------
4142-
SJKM1-400325710514915010036.5441956.5442253270120
4198
SJKM1-630327011818215510841582007582344070120
4240
SJKM1-800328210221015810334.5702437702434870125
4280
SJKM1-12503406104210190140.558.57037510-----
Handle H W Protrusion in the middle L W H
631713.56344225.5
125191312551235.5
2502212.525052234
40043.533.540089.5657
6304433.56309065.57
8004033.5800105615
1250514112501007816
◆ Appearance and installation dimensions of the plug-in type front-connected wiring
SJKM1 Plug-in Type Front Wiring Dimensions
◆ Appearance and installation dimensions of plug-in type rear-panel wiring
ModelWLAH1GG1abd
SJKM1-63751351828171550606
SJKM1-125921703850332860566.5
SJKM1-2501071864650334070547
SJKM1-40014428050604048881439
SJKM1-630182300656040531001239
SJKM1-80021229857100431291401439
◆ Outline and Installation Schematic Diagram of Withdrawable Device
SJKM1 Withdrawable Device Installation Diagram
◆ Outline and Installation Dimensions of Withdrawable Device
Model pole overall dimensions installation dimensions
L1L2L3H1H2H3W1W2φd1 ABφd2
SJKM1-400/M3P31033920325317.57748223φ1196134φ6.5
4P31033920325317.57748271φ11144134φ6.5
SJKM1-630/M3P34138121128217.59258253φ13116140φ6.5
4P34138121128217.59258311φ13174140φ6.5
SJKM1-800/M3P367410241238267370289φ13140131φ6.5
4P367410241238267370359φ13210131φ6.5

Frequently Asked Questions (FAQ)

What are the standard ambient operating temperatures for SJKM1 MCCBs?
The SJKM1 moulded case circuit breaker is engineered to operate reliably in ambient temperature conditions ranging from -5°C to +40°C. Custom builds are available for requirements outside this temperature threshold.
What is the altitude limitation for installing the SJKM1 circuit breaker?
The maximum recommended installation altitude is 2000 meters above sea level to maintain full technical ratings and electrical performance specifications.
Can the SJKM1 series be installed in orientations other than vertical?
Yes, the SJKM1 series features multi-directional mounting versatility. It can be mounted horizontally, vertically, or flat without derating its rated electrical performance.
What defines the differences between N-Pole Type A and Type B units?
Type A features an always-connected neutral pole without an over-current release element that does not open/close synchronously with the phase poles. Type B also lacks an over-current release element but opens and closes synchronously with phase poles (closing earlier and opening later).
What functionality is indicated by release codes 200 and 300?
Code 200 denotes an MCCB configuration equipped exclusively with an instantaneous electromagnetic release. Code 300 indicates a compound protection setup containing both thermal (overload) and electromagnetic (short-circuit) trip units.
What are the environmental protection grades and installation categories?
The entire SJKM1 series complies with standard industrial classifications featuring Pollution Degree Grade 3 and belongs to Installation Category III.