High-Quality China Suppliers SJKQ2Z ATS Automatic Transfer Switch for Dual Power 100A-1250A - Reliable Factory Solutions Manufacturers, Manufacturer

The SJKQ2Z ATS Automatic Transfer Switch is an essential solution for reliable power management, designed to seamlessly integrate with SJKM1 series circuit breakers. This high-performance switch is suitable for loads ranging from 100A to 1250A at 400V AC/50-60Hz, making it an ideal choice for critical backup systems in both industrial and commercial settings, Manufactured in China, this ATS boasts features such as adjustable delay timing from 0 to 30 seconds, a 2500V insulation withstand capacity, and a remarkable 5000-cycle mechanical endurance. With available 3P/4P configurations and an AC230V control voltage, the SJKQ2Z Automatic Transfer Switch ensures smooth transitions between primary and secondary power sources, effectively preventing flicker or breakdown during operation

Product Description

Type Designation
Q2Z-ATS-Switch-Dual-Power-5
1 Manufacturer Code
2 Auto-Transfer Function
3 Derivative Code:
(): NCCB; W Compact Type; W1: Economy Type; W2: Smart Type (Undervoltage / Phase-Loss / Off / Fire Protection)
4 Function Code:
R – Grid-to-Grid (Optional); F – Grid-to-Generator; M – Terminal Type (Optional);
Y – Integrated Smart Type (Off / Fire Protection / Undervoltage); N – Split Smart Type (Off / Fire Protection / Undervoltage)
5 Frame Size Current
6 Number of Poles
7 Rated Current (In)
Setting Program Instructions
SJKQ2Z-2
  • 1. LCD Display
  • 2. SET Button
  • 3. Right-Shift Button
  • 4. Increment Button (+)
  • 5. Decrement Button (−) / Alarm
  • 6. Manual Mode Button
  • 7. Auto Mode Button
  • 8. Dual-Off Button
Note: LCD display abbreviations: "auto-reclose" (AR), "No auto-reclose" (NAR), "SF01" must not be changed.
Step Key Press Display Data Operation Function
1 SET CodE Enter setting mode Password setup
2 >> OodE Press (︽ ︾) the first digit of the password Password setup
3 >> 80dE Press (︽ ︾) the second digit of the password Password setup
4 >> 880E Press (︽ ︾) the third digit of the password Password setup
5 >> 8888 Press (︽ ︾) the fourth digit of the password Password setup 8888
6 >> dddd / N-R 03s Correct password shows Normal-Backup transfer time Normal-Backup transfer time
Press (︽ ︾) to set N-R 1st-stage delay
7 >> N-R 03s Shows Normal-Backup transfer time Normal-Backup transfer time
Press (︽ ︾) to set N-R 2nd-stage delay
8 >> R-N 03s Shows Backup-Normal transfer time Backup-Normal transfer time
Press (︽ ︾) to set R-N 1st-stage delay
9 >> R-N 03s Shows Backup-Normal transfer time Backup-Normal transfer time
Press (︽ ︾) to set R-N 2nd-stage delay
10 >> SF 08s Show dual-off time Dual-off transfer time
Press to set SF 1st-stage delay
11 >> SF 08s Show dual-off time Dual-off transfer time
Press (︽ ︾) to set SF 2nd-stage delay
12 >> FFF 1 Press (︽ ︾) to set auto-recovery (1=ON, 0=OFF) ON / OFF
13 >> FD 0 Press (︽ ︾) full-auto generator mode to 0 and semi-auto model to 1 Starter Generator
14 >> FC 0 Press (︽ ︾) to set priority (0=Normal, 1=Backup) Priority setting
15 >> H 130 Press (︽ ︾) to set Overvoltage setting (220V × 130%) Overvoltage setting
16 >> L 50 Press (︽ ︾) to set Undervoltage setting (220V × 50%) Undervoltage setting
17 >> NA 220V Press (︽ ︾) to calibrate Normal Phase-A voltage Show live voltage
18 >> NB 220V Press (︽ ︾) to calibrate Normal Phase-B voltage Show live voltage
19 >> NC 220V Press (︽ ︾) to calibrate Normal Phase-C voltage Show live voltage
20 >> RA 220V Press (︽ ︾) to calibrate Backup Phase-A voltage Show live voltage
21 >> RB 220V Press (︽ ︾) to calibrate Backup Phase-B voltage Show live voltage
22 >> RC 220V Press (︽ ︾) to calibrate Backup Phase-C voltage Show live voltage
23 >> SAVE Save data
Product Display
Q2Z-ATS-Switch-Dual-Power-(1)
Q2Z-ATS-Switch-Dual-Power-(2)
Q2Z-ATS-Switch-Dual-Power-(3)
Q2Z-ATS-Switch-Dual-Power-(4)
Technical Parameters
Model Circuit Breaker Model Rack Current (A) Rated Operational Current
SJKQ2Z-100/3 SJKM1 series 100

225

400

630

800

1250
10 / 16 / 20 / 25 / 32 / 40 / 50 / 63 / 80 / 100
SJKQ2Z-100/4
SJKQ2Z-225/3 100 / 125 / 140 / 160 / 180 / 200 / 225
SJKQ2Z-225/4
SJKQ2Z-400/3 250 / 315 / 350 / 400
SJKQ2Z-400/4
SJKQ2Z-630/3 400 / 500 / 630
SJKQ2Z-630/4
SJKQ2Z-800/3 630 / 700 / 800
SJKQ2Z-800/4
SJKQ2Z-1250/3 800 / 1000 / 1250
SJKQ2Z-1250/4
Breaking Current (kA) Refer to the instruction manual of the specific circuit breaker model.
Rated Operational Voltage (V) 400V
Insulation Voltage (V) 2500 — No flicker and no breakdown within one minute
Frequency (Hz) 50–60 Hz
Delay Time 0–30s Adjustable
Control Rated Operating Voltage (V) AC 230V
Mechanical Life 5000 times
Outline and Installation Dimensions
SJKQ2Z-5
Size / Dimensions W W1 L L1 H
SJKQ2Z-100/3P390355220200120
SJKQ2Z-100/4P420385220200120
SJKQ2Z-225/3P430395220205140
SJKQ2Z-225/4P465435220205140
SJKQ2Z-400/3P560510310285190
SJKQ2Z-400/4P605555310285190
SJKQ2Z-630/3P625570320295195
SJKQ2Z-630/4P690635320295195
SJKQ2Z-800/3P705655340315190
SJKQ2Z-800/4P780730340315190
SJKQ2Z-1250/3P730675480365280
SJKQ2Z-1250/4P800745480365280
Installation and Usage Instructions
SJKQ2Z-7
  • 21: Normal Neutral Line
  • 22: Alternate Neutral Line
  • 23, 24: Normal Source ON Indicator Light
  • 25, 26: Alternate Source ON Indicator Light
  • 27, 28: Normal Source ON Indicator Light
  • 29, 30: Alternate Source ON Indicator Light
  • 31, 32: Duo Status Indicator Light
  • 33, 34: Fire Signal Input / AC or DC 6–24V Dry
  • 35, 36: Generator Contact (5A)
Frequently Asked Questions
What is the SJKQ2Z ATS Switch and what is it used for?
The SJKQ2Z is an Automatic Transfer Switch (ATS) designed for dual-power applications. It automatically transfers the load between a normal power source and a backup source (such as a generator or secondary grid supply), ensuring continuous power supply in the event of a primary source failure.
What are the available frame sizes and rated currents for the SJKQ2Z series?
The SJKQ2Z series is available in frame sizes of 100A, 225A, 400A, 630A, 800A, and 1250A, each offered in 3-pole and 4-pole configurations. Rated operational currents range from 10A up to 1250A depending on the selected model.
How do I enter the setting mode and what is the default password?
Press the SET button to enter setting mode. The display will show "CodE". Use the Right-Shift button (>>) and Increment/Decrement buttons (︽ ︾) to enter each digit of the password. The default password is 8888.
Can the transfer delay time be adjusted, and what is the adjustment range?
Yes, the transfer delay time is fully adjustable. Both Normal-to-Backup (N-R) and Backup-to-Normal (R-N) transfer times, as well as the dual-off time (SF), support two-stage delay configuration. The overall delay range is 0 to 30 seconds, adjustable through the setting program.
What is the rated operational voltage and what frequency does the SJKQ2Z support?
The SJKQ2Z ATS Switch is rated for an operational voltage of 400V AC. It supports a frequency range of 50–60 Hz, making it suitable for both international power grid standards.
What smart protection functions does the W2 derivative code offer?
The W2 smart type derivative code provides advanced protection functions including Undervoltage protection, Phase-Loss protection, Off-mode control, and Fire Protection signaling. These features make the W2 variant suitable for critical installations requiring enhanced safety and automation.