China SJK47LE-63 RCCB: Reliable Earth Leakage Protection - China Suppliers & Factory for 230V/400V AC Systems Manufacturers, Manufacturer

The SJK47LE-63 Residual Current Circuit Breaker (RCCB) is engineered to deliver dependable earth leakage and overcurrent protection for AC systems operating at 230V/400V (50Hz). As a leading product from a reputable China manufacturer and supplier, this RCCB is available in versatile configurations including 1P, 2P, 3P, and 4P, with current ratings ranging from 6A to 63A. It features advanced C/D-type tripping characteristics and is capable of withstanding short-circuit currents of up to 6000A, making it an ideal choice for both residential and commercial applications. The SJK47LE-63 ensures robust safety against electrical faults while providing stable performance in environments ranging from 30°C to 35°C. This product complies with international standards and boasts a compact design without compromising on reliability, making it a top choice among suppliers in the electrical protection market

Product Description

Type Designation
DZ47LE-63-6
1 Manufacturer Code
2 Design Serial Number
3 With Residual Current Protection (Earth Leakage Protection)
4 Rated Current Collection (32A, 63A)
5 Operational Current
6 Number of Poles
Product Display
Technical Parameters

Table 1

Maximum Frame-rated Current (A) Number of Poles With Neutral Pole Rated Current In (A) Rated Voltage Un (V) Rated Residual Operating Current I△n (mA) Rated Residual Non-operating Current I△no (mA) Breaking Time at I△n (s) Rated Residual Making & Breaking Capacity I△m (A) Instantaneous Overcurrent Release Type
32 1 +N 6
10
16
20
25
230 30
50
100
300
15
25
50
150
<0.1 2000 C
D
2 230
3 400
3 +N 400
4 400
63 1 +N 32
40
50
63
230
2 230
3 400
3 +N 400
4 400
◇ Rated Short-Circuit Capacity (Icn), Service Short-Circuit Breaking Capacity (Ics).

Table 2

Model Rated Current Rated Short-Circuit Current (A) Operating Short-Circuit Breaking Capacity (A)
SJK47LE 6~63A 4500 4500
SJK47LEH 6~63A 6000 6000
◇ Overcurrent Protection Characteristics at 30°C~35°C (Ref. Table 3)

Table 3

No. Rated Current of Release (A) Initial State Test Current Specified Time Expected Result Notes
1 6~63 Cold State 1.13In t≤1h In≤63A No Tripping
2 6~63 Immediately after previous test post-test condition 1.45In t<1h In≤63A Tripping Current Rises Steadily to Specified Value Within 5s
3 In≤32 Cold State 2.55In 1s<t<60s Tripping
In>32 Cold State 2.55In 1s<t<120s Tripping
4 6~63 Cold State 5In
10In
t≤0.1s
t<0.1s
No Tripping
Tripping
C Type
10In
14In
t≤0.1s
t<0.1s
No Tripping
Tripping
D Type
◇ Wiring: For conductors ≤25mm² (Ref. Table 4) 2N·m — Connection method: Screw-clamp terminals, Torque 2N·m

Table 4

Rated Current In (A) Nominal Cross-Sectional Area of Copper Conductor (mm²)
6 1
10 1.5
16、20 2.5
25 4
32 6
40、50 10
63 16
Outline and Installation Dimensions
DZ47LE-63-4

Table 5

1P+N 2P 3P 3P+N 4P
18+36 36+36 54+54 54+72 72+72
Frequently Asked Questions
Q What is the difference between SJK47LE and SJK47LEH models?
The SJK47LE has a rated short-circuit breaking capacity (Icn) of 4500A, while the SJK47LEH is a higher-performance variant with a rated short-circuit breaking capacity of 6000A. Both cover a rated current range of 6~63A, making SJK47LEH more suitable for installations requiring higher fault current protection.
Q What residual current (earth leakage) sensitivity options are available?
The SJK47LE-63 series offers four rated residual operating current (I△n) options: 30mA, 50mA, 100mA, and 300mA. The corresponding non-operating currents (I△no) are 15mA, 25mA, 50mA, and 150mA respectively. The breaking time at I△n is less than 0.1 seconds for all options.
Q What pole configurations are available for this circuit breaker?
The SJK47LE-63 is available in multiple pole configurations: 1P+N (single pole with neutral), 2P, 3P, 3P+N, and 4P. For 32A frame models, the rated voltage is 230V for 1P+N and 2P, and 400V for 3P, 3P+N, and 4P configurations.
Q What are the C-type and D-type instantaneous overcurrent release characteristics?
C-type breakers trip instantaneously (t<0.1s) at currents above 10In and do not trip at 5In. D-type breakers trip instantaneously (t<0.1s) at currents above 14In and do not trip at 10In. D-type is preferred for loads with high inrush currents such as motors and transformers, while C-type suits general residential and commercial loads.
Q What copper conductor size should I use with a 63A rated current breaker?
For a 63A rated current, a copper conductor with a nominal cross-sectional area of 16mm² is recommended. The connection method uses screw-clamp terminals with a tightening torque of 2N·m. Always refer to Table 4 for the correct conductor sizing for other current ratings ranging from 6A to 63A.
Q How much DIN rail space does the SJK47LE-63 occupy?
The installation width depends on the pole configuration. For example, a 1P+N model occupies 18+36mm, a 2P model occupies 36+36mm, a 3P model occupies 54+54mm, a 3P+N model occupies 54+72mm, and a 4P model occupies 72+72mm. This allows accurate panel planning and DIN rail space allocation.

Related Products