China China SJKM1 Moulded Case Circuit Breaker (MCCB) Factory | Reliable Power Protection from Leading Suppliers Manufacturer, Company

,

The SJKM1 Moulded Case Circuit Breaker (MCCB) is expertly engineered for AC power systems operating at 50/60Hz, accommodating voltages up to 690V and currents up to 1250A. This high-performance SJKM1 MCCB provides dependable protection against overloads, short circuits, and undervoltage conditions in diverse distribution networks. Models with frame sizes reaching 400A can effectively safeguard motors, making it an essential component for industrial and commercial applications. As a reliable product from a leading China factory, the SJKM1 complies with stringent standards such as IEC 60947-2 and GB14048.2, ensuring safe power distribution and optimal equipment protection. Its robust construction also supports infrequent switching and efficient motor starting. Choose our SJKM1 MCCB for reliable protection sourced from trusted suppliers in China.

,

Product Description

Type Designation
SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-5
①Manufacturer Code
②Molded Case Circuit Breaker Code
③Design Code
④Frame Size
⑤Short-Circuit Breaking Capacity Level 4
⑥Operation method 3
⑦Number of Poles 2
⑧Trip Unit Method & File Code
⑨Function Code 1
⑩Type code (See Table 1 for N-pole of four-pole, no code for three-pole)

Notes:

1. There is no code for distribution circuit breakers; for motor-protection circuit breakers, use 2 to represent.

2. Number of poles: 2 for two-pole; 3 for three-pole; 4 for four-pole.

3. For handle-direct operation: use D to represent for power-distribution use, and use Z to represent for conversion-locking use.

4. For economy type: represent with E; for standard type: represent with M; for higher-reliability type: represent with H; for high-breaking type: represent with L.

Product Display
N-pole Type Code
Type CodeDescription
Type ANo over-current release element is installed on the N-pole, and the N-pole is always connected, and does not close and open together with the other three poles.
Type BNo over-current release element is installed on the N-pole, and the N-pole closes and opens together with the other three poles (the N-pole closes first and opens later).
Type CAn over-current release element is installed on the N-pole, and the N-pole closes and opens together with the other three poles (the N-pole closes first and opens later).
Type DAn over-current release element is installed on the N-pole, and the N-pole is always connected, and does not close and open together with the other three poles.
Release Modes and Accessory Codes
Accessory Name Without Accessory Alarm Contact Shunt Release Auxiliary Contact Under-voltage Release Shunt Release Auxiliary Contact Two-group Auxiliary Contacts Shunt Release Under-voltage Release Auxiliary Contact Under-voltage Release
Release Mode Instantaneous Code 200208210220230240250260270
Release Mode Compound Code 300208310320330340350360370

(Continued from the previous table)

Accessory Name Shunt Release Alarm Contact Auxiliary Contact Alarm Contact Under-voltage Release Alarm Contact Shunt Release Auxiliary Contact Alarm Contact Two-group Auxiliary Contact Alarm Contact Auxiliary Contact Under-voltage Release Alarm Contact
Release Mode Instantaneous Code 218228238248268278
Release Mode Compound Code 318328338348268378

Notes:

1) 200 indicates the circuit breaker body with only an electromagnetic release; 300 indicates the circuit breaker body with thermal and electromagnetic releases.

2) For the two-level products SJKM1-125 and SJKM1-250, only 210, 310, 220, 320, 230, and 330 are available.

Normal Operating Conditions and Installation Conditions
Ambient temperature: The circuit breaker can operate normally at an ambient temperature range of -5°C to +40°C (except for special orders).
Altitude: The altitude of the installation site of the circuit breaker shall not exceed 2000m.
Pollution degree: The pollution degree of the circuit breaker is Grade 3.
Installation category: The installation category of the circuit breaker is Category III.
Installation position: The circuit breaker can be installed horizontally, vertically, or flat, without reducing its electrical performance.
Main Parameters and Technical Performances
Circuit Breaker Model SJKM1-63 SJKM1-125 SJKM1-250 SJKM1-400 SJKM1-630 SJKM1-800 SJKM1-1250
Pole Number 3432432434343434
Rated Current In A 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 125 100 125 140 160 180 200 225 250 225 250 315 350 400 400 500 630 630 700 800 800 1000 1250
Rated Insulation Voltage Ui (V) 690 1000 1000 1000 1000 1000 1000
Rated Impulse Withstand Voltage Uimp V 6000 8000
Rated Working Voltage Ue V 400 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690
Breaking Capacity Level LMLMHLMHLMHLMHHH
Ultimate Short-Circuit Breaking Capacity Icu (kA) (0-tCO) 400V 255035508535508550651005065100100100
690V 2525303025
Service Short-Circuit Breaking Capacity Ics (kA) (0-tCOtCO) 400V 18302535502535653550653550656550
690V 1515202020
Appearance and Installation Dimensions
Appearance and installation dimensions of the fixed-type front-connected and rear-connected wiring
Appearance and installation dimensions of fixed-type front and rear wiring
Model Number Overall Dimensions (mm) Mounting Dimensions (mm) Dimensions for Rear Terminal Wiring (mm)
LL1WHH1H2 abφd a1b1d1H3H4
SJKM1-63L31352176887219 251174 25117185275
SJKM1-63M978228
SJKM1-634103
SJKM1-125L1505192866824 301294.5 301322265100
SJKM1-125M31048623
SJKM1-125H
SJKM1-125265 ---
412230
SJKM1-250L165641071088725 351265.5 351442470110
SJKM1-250M3165107124.510424.5
SJKM1-250H
SJKM1-250275 --
4142
SJKM1-400325710514915010036.5 441956.5 442253270120
4198
SJKM1-630327011818215510841 582007 582344070120
4240
SJKM1-800328210221015810334.5 702437 702434870125
4280
SJKM1-12503406104210190140.558.5 7037510 ---
手柄HWProtrusion in the middleLWH
631713.56344225.5
125191312551235.5
2502212.525052234
40043.533.540089.5657
6304433.56309065.57
8004033.5800105615
1250514112501007816
Appearance and installation dimensions of the plug-in type front-connected wiring
SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (3)
Appearance and installation dimensions of plug-in type rear-panel wiring
ModelWLAH1GG1abd
SJKM1-63751351828171550606
SJKM1-125921703850332860566.5
SJKM1-2501071864650334070547
SJKM1-40014428050604048881439
SJKM1-630182300656040531001239
SJKM1-80021229857100431291401439
Outline and Installation Schematic Diagram of Withdrawable Device
SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (4)
Outline and Installation Dimensions of Withdrawable Device
Model Pole Overall Dimensions Installation Dimensions
L1L2L3H1H2H3W1W2φd1 ABφd2
SJKM1-400/M3P31033920325317.57748223φ1196134φ6.5
4P31033920325317.57748271φ11144134φ6.5
SJKM1-630/M3P34138121128217.59258253φ13116140φ6.5
4P34138121128217.59258311φ13174140φ6.5
SJKM1-800/M3P367410241238267370289φ13140131φ6.5
4P367410241238267370359φ13210131φ6.5
Frequently Asked Questions (FAQ)
What does the type designation code of the SJKM1 Molded Case Circuit Breaker represent?
The type designation code of the SJKM1 MCCB includes information about the manufacturer code, molded case circuit breaker code, design code, frame size, short-circuit breaking capacity level, operation method, number of poles, trip unit method & file code, function code, and N-pole type code. Each position in the code corresponds to a specific parameter of the product.
What are the differences between the N-pole types (A, B, C, D) in the SJKM1 MCCB?
Types A and B have no over-current release element on the N-pole. Type A keeps the N-pole always connected (independent of other poles), while Type B operates the N-pole together with the other three poles (closing first, opening last). Types C and D have an over-current release element on the N-pole. Type C operates with the other poles (closing first, opening last), while Type D keeps the N-pole always connected.
What are the normal operating and installation conditions for the SJKM1 MCCB?
The SJKM1 MCCB operates normally at ambient temperatures from -5°C to +40°C, at altitudes not exceeding 2000m, with a pollution degree of Grade 3 and installation category of Category III. It can be installed horizontally, vertically, or flat without any reduction in electrical performance.
What breaking capacity levels are available for the SJKM1 MCCB series, and what do they mean?
The SJKM1 MCCB series offers four breaking capacity levels: E (Economy type), M (Standard type), H (Higher-reliability type), and L (High-breaking type). These codes indicate the short-circuit breaking capability and design reliability of the circuit breaker, with higher levels offering increased breaking capacity values (Icu/Ics) at rated voltages.
What accessories are available for the SJKM1 MCCB, and how are they coded?
The SJKM1 MCCB supports a variety of accessories including alarm contacts, shunt releases, auxiliary contacts, under-voltage releases, and combinations thereof. Each configuration is assigned a specific numeric code (e.g., 200 for no accessory, 210 for shunt release only, 220 for auxiliary contact, etc.). Both instantaneous and compound release modes have separate code tables.
What frame sizes and rated current ranges are available in the SJKM1 MCCB series?
The SJKM1 MCCB series covers a wide range of frame sizes from SJKM1-63 up to SJKM1-1250. Rated current ranges vary by frame: SJKM1-63 covers 10A–63A, SJKM1-125 covers 16A–125A, SJKM1-250 covers 100A–250A, SJKM1-400 covers 225A–400A, SJKM1-630 covers 400A–630A, SJKM1-800 covers 630A–800A, and SJKM1-1250 covers 800A–1250A, available in 2-pole, 3-pole, and 4-pole configurations.

Related Products